<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet type="text/xsl" href="https://ejurnal.itenas.ac.id/lib/pkp/xml/oai2.xsl" ?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/
		http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
	<responseDate>2026-04-04T00:03:41Z</responseDate>
	<request from="2020-11-11" metadataPrefix="oai_dc" verb="ListRecords">https://ejurnal.itenas.ac.id/index.php/lingkungan/oai</request>
	<ListRecords>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.pkp.sfu.ca:article/186</identifier>
				<datestamp>2021-03-03T23:56:46Z</datestamp>
				<setSpec>rekaloka:ART</setSpec>
			</header>
		</record>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.pkp.sfu.ca:article/81</identifier>
				<datestamp>2021-03-01T22:05:39Z</datestamp>
				<setSpec>rekamakna:ART</setSpec>
			</header>
		</record>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/12148</identifier>
				<datestamp>2025-07-08T08:13:42Z</datestamp>
				<setSpec>rekaracana:ART</setSpec>
			</header>
		</record>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/7328</identifier>
				<datestamp>2022-08-18T18:50:16Z</datestamp>
				<setSpec>rekaracana:ART</setSpec>
			</header>
		</record>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.pkp.sfu.ca:article/86</identifier>
				<datestamp>2021-03-03T23:56:46Z</datestamp>
				<setSpec>rekaloka:ART</setSpec>
			</header>
		</record>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/14861</identifier>
				<datestamp>2026-02-20T08:15:11Z</datestamp>
				<setSpec>rekayasahijau:ART</setSpec>
			</header>
		</record>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.pkp.sfu.ca:article/192</identifier>
				<datestamp>2021-03-03T23:56:46Z</datestamp>
				<setSpec>rekaloka:ART</setSpec>
			</header>
		</record>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.pkp.sfu.ca:article/93</identifier>
				<datestamp>2021-03-01T22:05:39Z</datestamp>
				<setSpec>rekamakna:ART</setSpec>
			</header>
		</record>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/12826</identifier>
				<datestamp>2025-07-08T08:26:19Z</datestamp>
				<setSpec>rekaracana:ART</setSpec>
			</header>
		</record>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.pkp.sfu.ca:article/98</identifier>
				<datestamp>2021-03-03T23:56:46Z</datestamp>
				<setSpec>rekaloka:ART</setSpec>
			</header>
		</record>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/14862</identifier>
				<datestamp>2026-02-20T08:15:11Z</datestamp>
				<setSpec>rekayasahijau:ART</setSpec>
			</header>
		</record>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/8827</identifier>
				<datestamp>2023-11-17T21:00:49Z</datestamp>
				<setSpec>elkomika:ART</setSpec>
			</header>
		</record>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/5305</identifier>
				<datestamp>2021-08-02T17:06:20Z</datestamp>
				<setSpec>rekakarsa:ART</setSpec>
			</header>
		</record>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.pkp.sfu.ca:article/94</identifier>
				<datestamp>2021-03-01T22:05:39Z</datestamp>
				<setSpec>rekamakna:ART</setSpec>
			</header>
		</record>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/14196</identifier>
				<datestamp>2025-08-04T10:38:32Z</datestamp>
				<setSpec>REKAJIVA:ART</setSpec>
			</header>
		</record>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.pkp.sfu.ca:article/102</identifier>
				<datestamp>2021-03-03T23:56:46Z</datestamp>
				<setSpec>rekaloka:ART</setSpec>
			</header>
		</record>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/14863</identifier>
				<datestamp>2026-02-20T08:15:11Z</datestamp>
				<setSpec>rekayasahijau:ART</setSpec>
			</header>
		</record>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/13250</identifier>
				<datestamp>2025-02-02T00:22:50Z</datestamp>
				<setSpec>rekaracana:ART</setSpec>
			</header>
		</record>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/5981</identifier>
				<datestamp>2021-12-16T17:56:59Z</datestamp>
				<setSpec>rekaracana:ART</setSpec>
			</header>
		</record>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.pkp.sfu.ca:article/96</identifier>
				<datestamp>2021-03-01T22:05:39Z</datestamp>
				<setSpec>rekamakna:ART</setSpec>
			</header>
		</record>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/11668</identifier>
				<datestamp>2025-08-22T04:24:35Z</datestamp>
				<setSpec>REKAJIVA:ART</setSpec>
			</header>
		</record>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.pkp.sfu.ca:article/184</identifier>
				<datestamp>2021-03-03T23:56:46Z</datestamp>
				<setSpec>rekaloka:ART</setSpec>
			</header>
		</record>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/14864</identifier>
				<datestamp>2026-02-20T08:15:11Z</datestamp>
				<setSpec>rekayasahijau:ART</setSpec>
			</header>
		</record>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/13259</identifier>
				<datestamp>2025-07-06T03:51:50Z</datestamp>
				<setSpec>rekaracana:ART</setSpec>
			</header>
		</record>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/5248</identifier>
				<datestamp>2022-06-14T17:35:51Z</datestamp>
				<setSpec>rekaracana:ART</setSpec>
			</header>
		</record>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.pkp.sfu.ca:article/97</identifier>
				<datestamp>2021-03-01T22:05:39Z</datestamp>
				<setSpec>rekamakna:ART</setSpec>
			</header>
		</record>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/14860</identifier>
				<datestamp>2026-02-20T08:15:11Z</datestamp>
				<setSpec>rekayasahijau:ART</setSpec>
			</header>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/1205</identifier>
				<datestamp>2022-07-21T15:30:04Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Perencanaan Sistem Instalasi Plambing Air Buangan Gedung Hotel Tebu</dc:title>
	<dc:creator>Reza, Krishna Moch</dc:creator>
	<dc:creator>Pharmawati, Kancitra</dc:creator>
	<dc:creator>Nurprabowo, Anindito</dc:creator>
	<dc:subject xml:lang="id-ID"></dc:subject>
	<dc:description xml:lang="id-ID">ABSTRAK Perencanaanplambing air buanganpadagedung Hotel Tebu yang berlokasi di Kota Bandung dirancanguntukmemenuhi salah satu fasilitas sanitasi di dalam gedung Hotel Tebu.Sistem plambing air buangan yang direncanakan meliputi pembuatan jalur dan perhitungan dimensi pipagrey water, black water, danventberdasarkan acuan SNI 03-6481â€“2000 tentang sistem plambingdan SNI 03-7065-2005 tentang Tata Cara Perencanaan Sistem Plambing Dan Perhitungan Perkiraan penggunaan jumlah pipa dan aksesoris yang digunakan. Hasilperhitungan yang diperolehmenunjukan diameter pipagrey water 50 mm -100 mm, diameter pipa black water 100 mm dengankemiringanpipaadalah2%dandiameter ventadalah 32 mm -100 mm. Untukjenispipa yang digunakandalampenyaluran air buanganadalahjenispipa PVC. Pipa grey water yang dibutuhkan sepanjang 327,75 m. Pipa black water yang dibutuhkan sepanjang 255, 29 m. Pipa vent yang dibutuhkan sepanjang 86,02 m. Kebutuhan asesorisÂ  yang digunakan yaitu elbow90Â°, elbow45Â°, reducer, dan Y tee dengan diameter 32 mm â€“ 100 mm.Â Kata kunci:air buangan, diameter, plambing, sanitasi</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2017-04-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/1205</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v5i1.%p</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 5, No 1 (2017)</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/1205/1410</dc:relation>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/4128</identifier>
				<datestamp>2022-03-06T18:22:34Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Pengaruh Konsentrasi NaCl terhadap Parameter Elastik Pasir Tersaturasi</dc:title>
	<dc:creator>Qadafi, Muammar</dc:creator>
	<dc:creator>Malik, Usman</dc:creator>
	<dc:subject xml:lang="id-ID">Core Pasir Tersaturasi; Konsentrasi NaCl; Parameter Elastik</dc:subject>
	<dc:description xml:lang="id-ID">AbstrakTelah dilakukan penelitian mengenai pengaruh konsentrasi larutan natrium klorinda (NaCl) yang disaturasikan pada sampel (core) pasir terhadap parameter elastik. Core dibuat dengan diameter 7,5 cm dan panjang 10 cm. Core dicetak dengan tekanan sebesar 5,8Ã—104 N/m2. Core yang telah dicetak disaturasi dengan larutan NaCl yang divariasikan kosentrasinya dari 0 ppm hingga 360000 ppm (titik jenuh NaCl) selanjutnya dirambatkan gelombang seismik/elastik menggunakan Sonic Wave Analyzer (SOWAN), dari pengukuran ini akan diperoleh waktu tempuh gelombang (delay) pada sampel. Berdasarkan waktu tempuh, kecepatan gelombang primer dan sekunder pada Core diketahui. Hasil yang diperoleh berupa parameter elastisik dari Core seperti modulus Young, Modulus Bulk, Modulus Geser dan Konstanta Lame. Modulus Young Core berkisar antara 7,8Ã—107Pa-1,8Ã—109Pa, modulus Bulk sebesar 1,8Ã—107Pa-8,9Ã—108Pa, modulus geser antara 5,1Ã—107Pa-7,6Ã—108Pa dan Konstanta Lame berkisar antara 1,8Ã—108Pa-3,4Ã—109Pa.Â AbstractResearch has been carried out on the effect of saturated sodium chloride (NaCl) solution concentration in sand samples (cores) on elastic parameters. This research was conducted to determine the differences in the elastic core parameters according to the concentration of NaCl that saturates them. The cores are made with a diameter of 7.5 cm and a length of 10 cm. The cores are molded at a pressure of 5,8Ã—104 N/m2. The cores that have been printed are saturated with NaCl solution with varying concentrations from 0 ppm to 360000 ppm (saturation point of NaCl) then propagated seismic/elastic waves using a Sonic Wave Analyzer (SOWAN), from this measurement the wave travel time (delay) will be obtained in the sample. Based on the travel time, the primary and secondary wave velocities at the Core are known. The core elastic parameters was obtained such as Young's modulus, Bulk modulus, Shear modulus and Lame's constant. Young Core modulus ranges from 7,8Ã—107Pa-1,8Ã—109Pa, Bulk modulus of 1,8Ã—107Pa-8,9Ã—108Pa, shear modulus between 5,1Ã—107Pa-7,6Ã—108Pa and Lame Constant ranges between 1,8Ã—108Pa-3,4Ã—109Pa.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2021-06-04</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/4128</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v10i1.1-10</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 10, No 1 (2022); 1-10</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/4128/2565</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/9031</identifier>
				<datestamp>2024-01-18T23:56:24Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">ANALISIS KESENJANGAN DISTRIBUSI RUANG TERBUKA HIJAU TINGKAT PELAYANAN KOTA DAN KECAMATAN DARI SISI AKSESIBILITAS DENGAN METODE SPACE SYNTAX  (STUDI KASUS: KOTA BANDUNG)</dc:title>
	<dc:creator>Iscahyono, Achmad Fauzan</dc:creator>
	<dc:creator>Qolifah, Siti</dc:creator>
	<dc:creator>Kameswara, Byna</dc:creator>
	<dc:subject xml:lang="id-ID">ruang terbuka hijau; distribusi; aksesibilitas; space syntax</dc:subject>
	<dc:description xml:lang="id-ID">AbstrakKesenjangan distribusi ruang terbuka hijau di Kota Bandung membawa dampak tersendiri terhadap lingkungan. Selain itu, kesenjangan distribusi ruang terbuka hijau juga berpengaruh terhadap aksesibilitas masyarakat dalam pergerakan menuju ruang terbuka hijau tersebut. Studi ini bertujuan untuk mengidentifikasi tingkat kesenjangan distribusi ruang terbuka hijau tingkat pelayanan kota dan kecamatan di Kota Bandung. Studi ini memakai metode Space Syntax dengan bantuan software DepthmapX. Bersumber pada hasil analisis dalam studi ini, menunjukkan bahwa distribusi ruang terbuka hijau di Kota Bandung mempunyai tingkatan kesenjangan yang besar. Distribusi ruang terbuka hijau cenderung berada di bagian tengah dan barat yang berpengaruh terhadap kemudahan aksesibilitas. Selain itu, lokasi distribusi ruang terbuka hijau cenderung berada pada jaringan jalan yang kurang terhubung. Terdapat beberapa ruang terbuka hijau yang berpotensi untuk dikembangkan karena memiliki aksesibilitas yang sangat baik, yaitu Taman Balai Kota Bandung, Taman Alun Alun dan Taman Kiara Artha. Penelitian ini diharapkan dapat mengevaluasi keberadaan ruang terbuka hijau serta sebagai rekomendasi penentuan lokasi ruang terbuka hijau dengan kualitas yang baik yang mudah diakses oleh masyarakat.Kata kunci: ruang terbuka hijau, distribusi, aksesibilitas, space syntax.Â AbstractThe disparity in the distribution of public open spaces in Bandung City has its own impact on the environment. In addition, the disparity in the distribution of public open spaces also affects the accessibility of the community in moving towards these public open spaces. This study expects to determine the level of disparity in the distribution of public open spaces at the city and sub-district service levels in Bandung City. This study uses the Space Syntax method with the help of DepthmapX software. In view of the consequences of the examination in this study, it shows that the distribution of public open spaces in Bandung City has a high level of disparity. The distribution of public open spaces tends to be in the central and western parts which affect the ease of accessibility. In addition, the distribution locations of public open spaces tend to be on less connected road networks. There are several public open spaces that have the potential to be developed because they have excellent accessibility, namely Bandung City Hall Park, Alun Alun Park and Kiara Artha Park. This study is expected to evaluate the existence of public open spaces and as a recommendation for the location of public open spaces arrangement with great quality that is effectively open to the community.Keywords: public open space, distribution, accessibility, space syntax.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2024-01-18</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/9031</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v11i3.184-197</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 11, No 3 (2023); 184-197</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/9031/3540</dc:relation>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/downloadSuppFile/9031/740</dc:relation>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/downloadSuppFile/9031/741</dc:relation>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/downloadSuppFile/9031/742</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/7194</identifier>
				<datestamp>2023-10-31T01:58:14Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/12442</identifier>
				<datestamp>2025-07-02T08:03:41Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">KINERJA BLACK SOLDIER FLY LARVAES (BSFL), HERMETIA ILLUCENS L., DALAM PENGOLAHAN LUMPUR TINJA DENGAN PENCAMPURAN SAMPAH PERIKANAN DAN SAMPAH BUAH PIDADA</dc:title>
	<dc:creator>Amalia, Indi Azmi Rizka</dc:creator>
	<dc:creator>Putri, Dyah Wulandari</dc:creator>
	<dc:subject xml:lang="id-ID">black soldier fly larvaes, co-substrat, lumpur tinja, sanitasi</dc:subject>
	<dc:description xml:lang="id-ID">Sanitasi di Muara Gembong tergolong ‘belum layak’ karena toilet tidak terhubung dengan sistem pembuangan yang memadai, dan unit pengumpulan desentralisasi tidak sesuai standar nasional. Oleh karena itu, pengolahan lumpur tinja setempat dari sumbernya penting untuk meningkatkan akses sanitasi layak. Penggunaan Black Soldier Fly Larvaes (BSFL) untuk mengolah lumpur tinja merupakan pendekatan inovatif guna mengurangi volume lumpur tinja dan menghasilkan produk yang tinggi protein sebagai pakan ternak. Namun, lumpur tinja sebagai substrat BSFL tidak mendukung pertumbuhan optimal larva karena kandungan nutrisinya rendah. Untuk meningkatkan nutrisi, co-substrate berupa limbah perikanan (IKN) dan buah pidada (PDD) ditambahkan. Tujuh variasi substrat diformulasikan, dan sekitar 100 mg substrat/larva/hari diberikan selama 12 hari. Kinerja BSFL dipantau melalui survival rate (SR), waste reduction rate (WR), dan biomass conversion rate (BCR). Hasil menunjukkan penambahan IKN secara signifikan meningkatkan kinerja BSFL (P &lt; 0,05), dengan substrat 50% lumpur tinja + 50% IKN memberikan nilai SR, WR, dan BCR tertinggi. Sebaliknya, penambahan PDD menurunkan SR dan WR, terutama pada varian 50% lumpur tinja + 50% PDD (F1-S1).</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID">Kurita BSF dan Institut Teknologi Bandung</dc:contributor>
	<dc:date>2025-02-04</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/12442</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v12i3.241-253</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 12, No 3 (2024); 241-253</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/12442/3853</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/13611</identifier>
				<datestamp>2026-04-03T02:44:45Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">PENGOLAHAN LIMBAH CAIR LAUNDRY MENGGUNAKAN KOMBINASI ELEKTROKOAGULASI DENGAN PLAT ALUMINIUM DAN ADSORPSI DENGAN KARBON AKTIF TEMPURUNG LONTAR</dc:title>
	<dc:creator>Solo, Anna Apriani Maniuk</dc:creator>
	<dc:subject xml:lang="id-ID">Elektrokoagulasi; Adsorpsi; Laundry, Lontar, Aluminium.</dc:subject>
	<dc:description xml:lang="id-ID">Telah dilakukan penelitian tentang pengolahan limbah cair laundry menggunakan kombinasi metode elektrokoagulasi-adsorpsi. Penelitian ini bertujuan untuk menentukan kondisi optimum dalam penurunan total fosfat, MBAS, COD dan TSS dalam limbah cair laundry menggunakan kombinasi metode elektrokoagulasi-adsorpsi. Penelitian ini dilakukan pada berbagai variasi kondisi elektrokoagulasi dan adsorpsi. Adapun variasi dalam proses elektrokoagulasi diantaranya waktu elektrokoagulasi (20, 30,60, dan 90 menit) dan rapat arus (12,5; 25; dan 75 A/m2). Sedangkan variasi dalam proses adsorpsi diantaranya waktu kontak (30,60, dan 90 menit) dan massa karbon aktif tempurung lontar (KATL) (0,5; 1,5; dan 3,0 gram). Pengolahan limbah cair laundry diawali dengan proses elektrokoagulasi dengan pemberian rapat arus sebesar 25 A/m2 selama 30 menit. Selanjutnya air limbah diolah lebih lanjut pada unit adsorpsi. Hasil penelitian menunjukan metode elektrokoagulasi-adsorpsi ini mampu menurunkan parameter total fosfat, MBAS, COD, dan TSS dalam limbah cair laundry. Kombinasi proses ini menghasilkan efisiensi penyisihan total fosfat sebesar 95,57% (waktu adsorpsi 30 menit menggunakan 1,5 gram KATL); MBAS sebesar 85,22% (waktu adsorpsi 60 menit menggunakan 3,0 gram KATL); COD sebesar 96,21% (waktu adsorpsi 90 menit menggunakan 1,5 gram KATL); dan TSS sebesar 95,57% (waktu adsorpsi 90 menit menggunakan 3,0 gram KATL). Dalam Proses kombinasi ini berat aluminium yang terlarut sebesar 0,007 gr/L dengan konsumsi listrik sebesar 0,12 kWh/m3.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID">Direktorat Riset dan Pengabdian Masyarakat Kemendikbudristek</dc:contributor>
	<dc:date>2026-03-05</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/13611</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v13i2.103-117</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 13, No 2 (2025); 103-117</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/13611/4317</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/3137</identifier>
				<datestamp>2021-03-02T16:59:59Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Analisis Willingness To Pay Sistem Penyediaan Air Minum Menggunakan Contingent Valuation Method Di Kota Bandung  (Studi Kasus Pelanggan IPA Dago Pakar)</dc:title>
	<dc:creator>Yolinda, Yolinda</dc:creator>
	<dc:creator>PHARMAWATI, KANCITRA</dc:creator>
	<dc:subject xml:lang="id-ID"></dc:subject>
	<dc:description xml:lang="id-ID">AbstrakPDAM Tirtawening secara berkala mengkaji tarif air minum untuk mendukung perbaikan sistem penyediaan air minum di Kota Bandung. Kajian tarif air minum dari sisi pelanggan perlu dilihat untuk perbaikan pelayanan yang semakin meningkat sesuai harapan terutama dari sisi kuantitas, kontinuitas dan kualitasnya melalui kemauan membayar pelanggannya. Kemauan pelanggan membayar lebih dari yang biasa dibayarkan untuk barang lingkungan atau willingness to pay (WTP) dapat memberikan kontribusi untuk PDAM Tirtawening Kota Bandung. Besaran nilai WTP perlu diestimasi sehingga dapat memberikan gambaran tingkat kemauan membayar pelanggan dalam perbaikan pelayanan PDAM. Pelanggan PDAM dari IPA Dago Pakar menjadi objek penelitian ini dengan menggunakan Contigent Valuation Method (CVM). CVM merupakan suatu metoda teknik survei kepada responden tentang nilaiÂ  yang mereka berikan terhadap komoditi yang tidak memiliki pasar seperti barang lingkungan untuk mengestimasi nilai barang lingkungan secara komprehensif. Berdasarkan hasil penelitian, nilai rata-rata WTP responden dari IPA Dago Pakar yang diperoleh adalah Rp. 130.857 per bulan dan nilai total WTP sebesar Rp 394.665.143. Nilai WTP tersebut dipengaruhi aspek pelayanan air minum yang dirasakan responden memuaskan. Pelaksanaan CVM dalam penelitian ini memiliki nilai R2 sebesar 0,816 atau 81,6% sehingga pelaksanaan metoda tersebut dapat diandalkan.Kata kunci: sistem penyediaan air minum, tarif, IPA Dago Pakar, CVM, WTP</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2019-09-03</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/3137</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v7i2.78-89</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 7, No 2 (2019); 78-89</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/3137/2009</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/7070</identifier>
				<datestamp>2023-07-03T02:59:19Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">APLIKASI ANODA MAGNESIUM PADA PROSES ELEKTRODIALISIS UNTUK RECOVERY NUTRIEN LIMBAH URINE</dc:title>
	<dc:creator>Rum, Mas Den</dc:creator>
	<dc:creator>Anggrainy, Anita Dwi</dc:creator>
	<dc:creator>Bagastyo, Arseto Yekti</dc:creator>
	<dc:subject xml:lang="id-ID">anoda magnesium, elektrodialisis, struvite, urine</dc:subject>
	<dc:description xml:lang="id-ID">Elektrodialisis untuk proses recovery nutrien dari urine sangat diminati pada satu dekade terakhir, karena dapat mengkonsentrasikan ion yang menjadi target untuk mendapatkan produk hasil recovery dengan tingkat kemurnian tinggi. Penggunaan magnesium sebagai anoda untuk proses elektrodialisis saat ini juga mengemuka. Anoda ini secara efektif dapat menghasilkan struvite tanpa memerlukan tambahan bahan kimia untuk penyesuaian pH larutan dalam reaksi presipitasi. Pada studi ini, efektifitas anoda magnesium untuk proses recovery nutrien dengan elektrodialisis diinvestigasi berdasarkan tiga variasi pH (8,5; 8,8; 9,0) dan dua variasi kuat arus (300 dan 450 mA). Tujuannya untuk mengevaluasi efisiensi recovery amonium dan fosfat, serta mengidentifikasi karakteristik presipitat. Selama eksperimen, penyesuaian pH larutan tetap dilakukan sesuai variasi pH awal (pH 8,5-9). Hasil menunjukkan bahwa recovery tertinggi amonium dan fosfat didapat pada pH 8.5. Sekitar 42% amonium dan 28% fosfat dapat diambil sebagai produk recovery masing-masing pada kuat arus 300 dan 450 mA. Lebih dari 90% brucite, 3% hydroxyapatite, dan 3% struvite dapat diidentifikasi sebagai produk presipitat.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2023-06-15</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/7070</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v11i1.12-23</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 11, No 1 (2023); 12-23</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/7070/3319</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/9493</identifier>
				<datestamp>2024-10-21T21:41:20Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">PENENTUAN STATUS MUTU AIR DAN STATUS TROFIK EMBUNG BRIGIF, KOTA CIMAHI</dc:title>
	<dc:creator>Wardhani, Eka</dc:creator>
	<dc:creator>Rachmanita, Fitra Insyirah</dc:creator>
	<dc:subject xml:lang="id-ID">indeks pencemar; status trofik; embung; Cimahi</dc:subject>
	<dc:description xml:lang="id-ID">Kebutuhan air bersih Kota Cimahi lebih besar dari ketersediaannya. Perlu dilakukan upaya peningkatan ketersediaan air dengan merehabilitasi embung. Embung Brigif merupakan salah satu yang dapat dimanfaatkan sebagai sumber air baku. Tujuan penelitian yaitu menentukan kualitas air dan status trofik embung sehingga dapat menjadi data dasar dalam melakukan perbaikan. Analisis kualitas air mengacu pada metode Indeks Pencemaran, berdasarkan Keputusan Menteri Lingkungan Hidup No. 115 Tahun 2003. Baku mutu yang menggunakan Peraturan Pemerintah Nomor 22 Tahun 2021 tentang Perlindungan dan Pengelolaan Lingkungan Hidup lampiran IV tentang baku mutu air danau kelas I. Status trofik menggunakan metode UNEP-ILEC menurut Peraturan Menteri Negara Lingkungan Hidup No. 28 Tahun 2009 Tentang Daya Tampung Beban Pencemaran air Danau dan Waduk dan metode Trophic State Index (TSI). Kedua metode tersebut menggunakan konsentrasi rata-rata total N , total P, jumlah khlorofil-a, dan kecerahan air danau. Berdasarkan hasil perhitungan status mutu air danau termasuk katagori tercemar sedang pada tahun 2021 dan 2022. Status tropik menggunakan kedua metode termasuk katagori hypereutrof. Status tropik tersebut sesuai dengan kondisi embung yang telah tercemar oleh limbah yang berasal dari daerah tangkapan air embung tersebut.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2024-10-22</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/9493</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v12i2.133-144</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 12, No 2 (2024); 133-144</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/9493/3733</dc:relation>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/downloadSuppFile/9493/783</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/737</identifier>
				<datestamp>2022-07-20T04:48:43Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Pemilihan Skenario Kebutuhan Air Minum pada Pengembangan Jaringan Distribusi Air Minum di Kecamatan Cipondoh, Kota Tangerang, Provinsi Banten</dc:title>
	<dc:creator>Yosua, Henry</dc:creator>
	<dc:creator>Sururi, Mohamad Rangga</dc:creator>
	<dc:subject xml:lang="id-ID"></dc:subject>
	<dc:description xml:lang="id-ID">Abstrak Kecamatan Cipondoh adalah bagian dari Kota Tangerang yang akan dikembangkan sebagai kawasan permukiman menengah, rendah serta perdagangan dan jasaÂ  skala regional. Luas wilayah adalah sebesar 1.938,1 Ha yang terbagi kedalam sepuluh kelurahan. Kecamatan Cipondoh membutuhkan pengembangan pelayanan air bersih karena PDAM hanya dapat melayani 3,5% dari jumlah penduduk di Kecamatan Cipondoh. Kecamatan Cipondoh juga memiliki jumlah kejadian penyakit bawaan air terbanyak di Kota Tangerang. Evaluasi terhadap jaringan eksisting menunjukkan sisa tekan antara 59,97 m - 40,52 m, kecepatan antara 0,02 m/detik - 0,73 m/detik, headloss maksimum sebesar 7,55 m/km. Hasil perhitungan diperoleh dari software Epanet 2.0. Pada perencanaan jaringan distribusi yang baru, perlu diperhitungkan dengan baik kebutuhan air yang akan dialokasikan untuk suatu wilayah perencanaan. Periode perencanaan adalah 20 tahun dengan skenario pertama adalah optimasi jaringan dengan cakupan pelayanan yang disesuaikan dengan kemampuan keuangan daerah dan skenario kedua adalah meningkatkan cakupan hingga 80% pelayanan dengan adanya bantuan pihak luar. Berdasarkan analisa ditinjau dari aspek teknis dan non teknis, skenario kedua dipilih sebagai acuan perencanaan. Qrata-rata sebesar 1.260,81 l/dtk, Qpeak sebesar 2.912,48 l/dtk.Kata kunci: kebutuhan air minum, pengembangan jaringan distribusi, Tangerang, Cipondoh.Â </dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2015-10-05</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/737</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v3i2.%p</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 3, No 2 (2015); 86-96</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/737/934</dc:relation>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/3129</identifier>
				<datestamp>2021-03-02T16:04:07Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Identifikasi Pencemaran Logam Berat Timbal (Pb) dan Seng (Zn) di Air Permukaan dan Sedimen Waduk Saguling Provinsi Jawa Barat</dc:title>
	<dc:creator>ADANI, JULIA PUTRI</dc:creator>
	<dc:creator>WARDHANI, EKA</dc:creator>
	<dc:creator>PHARMAWATI, KANCITRA</dc:creator>
	<dc:subject xml:lang="id-ID"></dc:subject>
	<dc:description xml:lang="id-ID">AbstrakSeiring peningkatan aktivitas masyarakat di sekitarnya, pencemaran Waduk Saguling terus meningkat. Parameter yang mencemarinya seperti logam berat Pb dan Zn. Penelitian ini bertujuan untuk menganalisis konsentrasi Pb dan Zn yang terkandung dalam perairan dan sedimen Waduk Saguling, serta mengidentifikasi hubungan parameter fisika kimia air dengan kelarutan logam berat. Kandungan logam berat Pb dan Zn dianalisis menggunakan metode Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Hasil penelitian diperoleh bahwa konsentrasi Pb dari dua belas lokasi sampling memiliki kisaran antara 0,0005-0,0421 mg/L. Kandungan Pb terendah terdapat pada titik Muara Ciminyak dan yang tertinggi pada lokasi Nanjung. Konsentrasi Zn pada perairan berkisar antara 0,1441-0,5976 mg/L dan telah melebihi baku mutu PP No. 82 Tahun 2001 Kelas II. Pada sedimen, konsentrasi Pb berkisar antara 7,9750-26,7217 mg/kg dan masih memenuhi baku mutu ANZECC (2000), sedangkan logam berat Zn berkisar antara 38,9333-234,8783 mg/kg, hanya lokasi Nanjung yang melebihi baku mutu. Kata kunci: Inductively Coupled Plasma (ICP-MS), Seng, Timbal, Waduk Saguling</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2019-09-03</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/3129</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v6i2.%p</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 6, No 2 (2018)</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/3129/2004</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/5963</identifier>
				<datestamp>2022-12-17T17:36:16Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">PERUBAHAN IKLIM SEBAGAI ANCAMAN KETAHANAN KUALITAS AIR PADA DAERAH ALIRAN SUNGAI: LITERATUR REVIEW</dc:title>
	<dc:creator>Nufutomo, Tastaptyani Kurnia</dc:creator>
	<dc:subject xml:lang="id-ID">Perubahan Iklim, Ketahanan Air, Kualitas Air, Daerah Aliran Sungai</dc:subject>
	<dc:description xml:lang="id-ID">Pada saat ini perubahan iklim sedang dialami secara global yang dampaknya diperkirakan akan sama seperti pandemi. Perubahan iklim terdiri dari empat faktor utama yaitu terjadinya peningkatan suhu atmosfer, perubahan pola curah hujan, peningkatan konsentrasi CO2 di atmosfer dan peningkatan kadar ozon di troposfer (O3). Dampak perubahan iklim yang biasanya diketahui adalah menurunnya ketersediaan air, sedangkan hubungannya dengan kualitas air masih kurang dipahami. Tujuan literatur review pada makalah ini adalah sebagai kumpulan referensi untuk mengetahui terdapat dampak perubahan iklim terhadap kualitas air di Daerah Aliran Sungai dan sebagai pencarian state of art untuk gap yang akan dilakukan pada penelitian selanjutnya. Pada makalah ini akan membahas mengenai pembagian iklim, Dampak Perubahan Iklim di Indonesia terhadap Sumber Daya Air, kondisi kualitas air sungai, dan ketahanan air terhadap perubahan iklim serta peraturan dan kebijakan di Indonesia mengenai pengelolaan sumberdaya air di Indonesia dan klimatologi. Metode yang digunakan dalam literatur review ini adalah menggunakan kata kunci dampak perubahan iklim pada pencarian di website jurnalÂ  seperti di Google scholar, Scopus dan Science directÂ  dengan rentan waktu 5 sampai 10 tahun (2011 â€“ 2021).</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID">Beasiswa Institut Teknologi Sumatera</dc:contributor>
	<dc:date>2022-11-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/5963</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v10i3.188-200</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 10, No 3 (2022); 188-200</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/5963/3087</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/10478</identifier>
				<datestamp>2024-07-16T07:42:26Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">PREDICTION OF HIGHER HEATING VALUE OF VARIOUS BIOMASSES USING THE EQUATION FOR THE HYDROTHERMAL CARBONIZATION METHOD ON BANANA BUNCHES</dc:title>
	<dc:creator>Sulaiman, Sani Maulana</dc:creator>
	<dc:creator>Nugroho, Gunawan</dc:creator>
	<dc:creator>Putra, Herlian Eriska</dc:creator>
	<dc:creator>Fitria, Novi</dc:creator>
	<dc:creator>Sukmawati, Wina Ike</dc:creator>
	<dc:subject xml:lang="en-US">HHV Prediction, Banana Bunch, HTC.</dc:subject>
	<dc:description xml:lang="en-US">When designing many variables influence the thermal conversion system for homogeneous biomass and heterogeneous biomass. The factor that can have an important influence is the higher the calorific value (HHV). Many correlation models have been developed to estimate the HHV of homogeneous and heterogeneous biomass to reduce analysis costs. Unfortunately, the correlation model for predicting biomass HHV still has shortcomings when predicting biomass data from different thermal conversion processes and different types of biomass. In this study, four new correlations based on proximate and ultimate analysis of homogeneous biomass with the hydrothermal carbonization (HTC) method used for HHV prediction are presented. The multiple linear regression method is used to produce correlations from homogeneous biomass data then compare biomass models from open literature and compare correlation accuracy for data from the literature. It was found that the correlation obtained from proximate analysis (HHV =967.171 -8.684Ash -9.299VM -9.913FC) was more accurate than that obtained from proximate.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2024-07-16</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/10478</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v12i1.81-92</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 12, No 1 (2024); 81-92</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/10478/3678</dc:relation>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/downloadSuppFile/10478/904</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/512</identifier>
				<datestamp>2021-03-12T22:39:40Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Pengaruh Karakteristik Lindi terhadap Ozonisasi Konvensional dan Advanced Oxidation Processes (Aop)</dc:title>
	<dc:creator>Krisnawati, Amalia</dc:creator>
	<dc:creator>Sururi, M. Rangga</dc:creator>
	<dc:creator>Ainun, Siti</dc:creator>
	<dc:subject xml:lang="id-ID"></dc:subject>
	<dc:description xml:lang="id-ID">ABSTRAKÂ Ozon merupakan oksidator kuat dalam air namun proses dekomposisinya dapat menghasilkan oksidator yang lebih kuat yaitu OH radikal. Penggunaan OH radikal sebagai pengolah air disebut Advanced Oxidation Processes (AOP) yang dapat digunakan pada limbah dengan bahan pencemar berat seperti lindi. Penelitian ini dilakukan untuk mengetahui pengaruh penambahan inisiator yaitu Hidrogen peroksida (H2O2) dan sinar UV-C pada dekomposisi ozon menjadi OH radikal. Proses ozonisasi dilakukan selama 180 menit pada ozon kontaktor berbentuk silinder bervolume 1,5 liter. Ozon dihasilkan dari oksigen murni yang melewati ozon generator. Hasil yang diperoleh yaitu ozonisasi dengan penambahan H2O2 mampu mengefektifkan pembentukkan OH radikal sebesar 50% sedangkan penambahan sinar UV mengefektifkan 37%. OH radikal tersebut menyebabkan perubahan karakteristik lindi sebesar Â 5-7% pada parameter pH, 21-33% pada parameter alkalinitas dan 18,7-29% pada parameter Chemical Oxygen Demand (COD). Kombinasi ozon/H2O2 memberikan perubahan yang paling tinggi dibandingkan dengan ozonisasi konvensional dan ozon/UV.Â Kata kunci : Lindi, Ozonisasi, AOP, Konsentrasi sisa ozon </dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2014-10-14</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/512</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v2i2.%p</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 2, No 2 (2014); 50-57</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/512/718</dc:relation>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/13708</identifier>
				<datestamp>2026-02-22T05:50:43Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">EVALUASI HIDROLIS MENGGUNAKAN EPANET 2.2 PADA PIPA DISTRIBUSI AIR MINUM DI DMA 2.8 ZONA 2 SPAM GEDEBAGE, KOTA BANDUNG</dc:title>
	<dc:creator>Hermawan, Hendra</dc:creator>
	<dc:creator>Sururi, Mohamad Rangga</dc:creator>
	<dc:creator>Permadi, Didin Agustian</dc:creator>
	<dc:subject xml:lang="id-ID">EPANET, evaluasi hidrolis pipa, Kecamatan Buahbatu, SPAM Gedebage</dc:subject>
	<dc:description xml:lang="id-ID">Target RPJMN Tahun 2020-2024 untuk SPAM perpipaan adalah peningkatan akses air minum menjadi 100%, yang meliputi peningkatan jaringan perpipaan menjadi 30% dan penurunan tingkat NRW menjadi 25%. Oleh karena itu, PERUMDA Tirtawening melaksanakan peningkatan pelayanan SPAM perpipaan di Blok Gedebage dengan memanfaatkan sistem DMA untuk memenuhi target RPJMN. Terdapat 23 DMA yang dipasang, termasuk DMA 2.8 yang berada pada Kelurahan Margasari, Kecamatan Buahbatu, Kota Bandung, yang mampu melayani 2.146 SR dengan panjang pipa distribusi 12.972 meter. Metodologi penelitian ini melibatkan penelusuran jalur yang terpasang di lapangan, diikuti dengan melakukan simulasi hidrolis pada jalur tersebut. Simulasi menggunakan software EPANET 2.2, yang melibatkan data berupa tingkat konsumsi air, elevasi tanah, pola penggunaan air, serta data teknis jaringan distribusi. Hasil simulasinya dievaluasi dengan syarat hidrolis yang diatur oleh Permen PU No. 18 Tahun 2007. Hasil evaluasi mengindikasikan bahwasanya semua nodes memenuhi standar sisa tekan (10-80) m/km, 66% links menunjukkan kecepatan di bawah 0,3 m/detik, dan 2% links menunjukkan headloss melebihi 10 m/km. Perbaikan dapat dilakukan dengan memperkecil diameter pipa pada 66% links hingga kecepatannya berada pada 0,3-3,0 m/detik dan memperbesar diameter pipa pada 2% links hingga headloss berada di bawah 10 m/km.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2025-10-28</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/13708</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v13i1.37-48</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 13, No 1 (2025); 37-48</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/13708/4103</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/1881</identifier>
				<datestamp>2021-03-02T15:01:42Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Penyusunan Rantai Pasok pada Rencana Pengamanan Air Minum (RPAM) Operator untuk Sumber Mata Air di PDAM Tirta Raharja Kabupaten Bandung</dc:title>
	<dc:creator>AZIZAH, ARINA NUR</dc:creator>
	<dc:creator>S.DJ, RACHMAWATI</dc:creator>
	<dc:creator>HANDAYANI, DYAH ASRI</dc:creator>
	<dc:subject xml:lang="id-ID"></dc:subject>
	<dc:description xml:lang="id-ID">AbstrakRencana Pembangunan Jangka Menengah Nasional (RPJMN) 2015-2019 menetapkan target 100% akses sumber air bersih dengan tujuan terpenuhinya penyediaan air minum untuk memenuhi kebutuhan masyarakat.Seiring dengan target RPJMN, PP No. 122 tahun 2015 menyatakan bahwa pemerintah wajib menjamin ketersediaan air baku yang memenuhi baku mutu yang ditetapkan untuk penyediaan air minum sesuai dengan peraturan. PDAM Tirta Raharja Kab. Bandung sebagai objek kajian, memiliki 9 Sistem Penyediaan Air Minum (SPAM) dengan 12 titik sumber air baku mata airÂ  yang menghasilkan debit produksi total sebesar 118 L/detik yang berpotensi dan selain itu memiliki beberapa kejadian bahaya yang berkaitan dengan aspek penyediaan air minum.Dokumen Rencana Pengamanan Air Minum (RPAM)adalah adaptasi dari program Water Safety Plan (WSP) WHOsebagai upaya mitigasi kejadian bahaya yang digagas oleh pemerintah. Komponen awal RPAM adalah pembuatan rantai pasok.Rantai pasoksebagai pokok kajian memiliki tujuan untuk mendeskripsikan setiap komponenunit Sistem Penyediaan Air Minum (SPAM). Penyusunan dilakukan dengan cara inventarisasi dari dokumen PDAM terkait, observasi lapangan, dan wawancara dengan pihak PDAM. Kajian ini menghasilkan 9 buah rantai pasok yang terbagi berdasarkan tingkat kompleksitas SPAM, merujuk pada jumlah dan jenis unit SPAM serta wilayah pelayanan SPAM. Adapun klasifikasi yang diperoleh adalah satu buah rantai pasok kompleks, lima buah rantai pasok menengah, dan tiga buah rantai pasok sederhana. Rantai pasok dapat menjadi referensi bagi PDAM untukmelakukan identifikasi kejadian bahaya dan risiko yang dapat ditimbulkan.Kata kunci: Rantai Pasok, SPAM, RPAM, Mata Air, PDAM Tirta Raharja Kab. Bandung.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2018-04-17</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/1881</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v6i1.%p</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 6, No 1 (2018)</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/1881/1751</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/4600</identifier>
				<datestamp>2022-03-06T18:22:34Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Pemilihan Sistem Pengelolaan Air Limbah Domestik di DAS Cisangkan</dc:title>
	<dc:creator>Wardhani, Eka</dc:creator>
	<dc:creator>Rosmeiliyana, Rosmeiliyana</dc:creator>
	<dc:subject xml:lang="id-ID">Sungai Cisangkan, limbah, domestik, pengelolaan</dc:subject>
	<dc:description xml:lang="id-ID">AbstrakKota Cimahi merupakan wilayah penyumbang beban pencemaran yang besar terhadap Sungai Citarum. Terdapat 5 sungai di Kota Cimahi yang terindikasi tercemar berat diantaranya adalah Sungai Cisangkan. DAS Cisangkan ditempati oleh penduduk dengan kepadatan tinggi dan belum dilengkapi dengan sistem pengelolaan air limbah domestik. Penelitian ini bertujuan untuk mengetahui strategi pengendalian pencemaran air yang sesuai untuk Sungai Cisangkan. Pengendalian difokuskan kepada air limbah domestik sesuai dengan PerMenPUPR No. 4 Tahun 2017. Hasil penelitian menyebutkan bahwa mutu air Sungai Cisangkan masuk katagori cemar berat dengan parameter yang tidak memenuhi bakumutu diantaranya BOD, COD, TSS, Fecal coli dan Total Coli. Â DAS Cisangkan meliputi 10 kelurahan, berdasarkan hasil penapisan 7 diantaranya akan menerapkan sistem terpusat dan 3 kelurahan menerapkan sistem setempat. Pengelolaan secara terpusat akan menggunakan perpipaan yang akan menyalurkan ke instalasi pengolahan air limbah. Sistem setempat direncanakan dengan menggunakan tangki septik biofilter berkapasitas 200 kepala keluarga per unit.Kata kunci: Sungai Cisangkan, limbah, domestik, pengelolaanAbstractCimahi City is an area that contributes a large pollution load to the Citarum River. There are five rivers in Cimahi City that are indicated to be heavily polluted, including the Cisangkan River. The Cisangkan watershed is occupied by a high- density population and is not equipped with a domestic wastewater management system. This study aims to determine the appropriate water pollution control strategy for the Cisangkan River. Control is focused on domestic wastewater in accordance with the regulation of the Minister of Public Works and Public Housing No. 4/2017. The results stated that the quality of Cisangkan River water was categorized as heavily polluted with parameters that did not meet the quality standards, including BOD, COD, TSS, Fecal Coli and Total Coli. The Cisangkan watershed covers ten sub-districts; based on the results of the screening, 7 of them will implement a centralized system, and three villages will apply the local system. Centralized management will use piping that will supply the wastewater treatment plant. The local system is planned using a biofilter septic tank with a capacity of 200 households per unit.Keywords: Cisangkan River, domestic, wastewater, management</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2021-06-04</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/4600</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v10i1.67-78</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 10, No 1 (2022); 67-78</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/4600/2572</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/7248</identifier>
				<datestamp>2023-10-31T02:25:10Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">EFEKTIVITAS AKTIVATOR MIKROORGANISME LOKAL LIMBAH SAYUR, EM4, DAN KOTORAN SAPI DALAM PEMBUATAN KOMPOS DARI LIMBAH SAYUR DI PASAR FLAMBOYAN</dc:title>
	<dc:creator>Dewantari, Ukhfiya</dc:creator>
	<dc:creator>arifin, Arifin</dc:creator>
	<dc:creator>Sulastri, Aini</dc:creator>
	<dc:subject xml:lang="id-ID">Aktivator, Kompos, Mikroorganisme Lokal</dc:subject>
	<dc:description xml:lang="id-ID">Flamboyan adalah pasar yang berlokasi di Kota Pontianak yang menghasilkan sampah organik dengan persentase sebesar 89,57 %. Tingginya sampah organik yang dihasilkan dapat menyebabkan limbah organik akan membusuk dan menimbulkan bau yang tidak sedap serta menjadi vektor penyakit sehingga sanitasi dan estetika lingkungan menurun. Oleh karena itu perlu dilakukan untuk menangani limbah tersebut dengan cara pengomposan. Tujuan penelitian ini yaitu mengetahui kualitas fisik dan kimia kompos berdasarkan PERMENTAN No. 70 tahun 2011 dan mengidentifikasi pengaruh antara aktivator mikroorganisme lokal limbah sayur, EM4 dan kotoran sapi terhadap kualitas kematangan kompos. Metode penelitian ini yaitu pengomposan secara aerobik dengan waktu pengomposan selama 35 hari dan menggunakan jumlah mikroorganisme yang sama yaitu sebanyak 7.850.000 sel. Hasil penelitian yang didapat, kompos yang terbaik terdapat pada aktivator kotoran sapi dengan parameter yang telah memenuhi baku mutu terdiri dari suhu sebesar 31oC, pH sebesar 5,8 , warna coklat kehitaman, bau seperti tanah, bertekstur halus, kadar kalium (K) sebesar 4,4 %, kadar C-Organik 32,9% dan rasio C/N kompos sebesar 23,54 serta aktivator MOL, EM4 dan kotoran sapi tidak memberikan pengaruh yang berbeda terhadap kematangan kompos.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2023-10-31</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/7248</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v11i2.117-129</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 11, No 2 (2023); 117-129</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/7248/3442</dc:relation>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/downloadSuppFile/7248/528</dc:relation>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/downloadSuppFile/7248/611</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/12430</identifier>
				<datestamp>2025-07-02T08:03:41Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">PENGARUH BEBAN INFLUEN TERHADAP PERFORMA PENGOLAHAN AIR LIMBAH DOMESTIK MENGGUNAKAN FIXED BED SYSTEM DENGAN MEDIA PENUNJANG PVC SARANG TAWON</dc:title>
	<dc:creator>Rizka, Miftahir</dc:creator>
	<dc:creator>Fauzi, Mhd.</dc:creator>
	<dc:creator>Soewondo, Prayatni</dc:creator>
	<dc:creator>Handajani, Marisa</dc:creator>
	<dc:creator>Tedjakusuma, Teddy</dc:creator>
	<dc:subject xml:lang="id-ID">air limbah domestik artifisial, anoxic fixed bed system, media PVC sarang tawon, variasi konsentrasi influen</dc:subject>
	<dc:description xml:lang="id-ID">Fixed Bed System merupakan teknologi yang efektif dalam menyisihkan polutan yang media PVC sarang tawon sebagai tempat terlekatnya biofilm. Tujuan dari penelitian ini adalah untuk melihat bagaimana penyisihan organik dan nutrien serta kinetika penyisihan substrat dari reaktor ini yang dioperasikan secara anoksik dengan sistem batch. Sistem anoksik dirancang dengan kandungan oksigen terlarut sekecil mungkin hingga mendekati nol. Air limbah yang digunakan adalah air limbah domestik artifisial dimana sumber karbon, nitrogen, dan fosfor berasal dari senyawa C6H12O6, NH4Cl, dan KH2PO4. Terdapat variasi konsentrasi influen yang masuk yaitu 300, 400, 500, 600, dan 700 mg/L. Berdasarkan hasil penelitian, didapatkan bahwa fixed bed system dengan proses anoxic dapat menyisihkan organik dan nutrien dengan baik. Efisiensi penyisihan COD adalah 84,75±0,6%, ammonia 53,21±0,5%, nitrit 55,46±0,7%, nitrat 91,28±0,5%, NTK 57,34±0,7%, N organik 68,49±0,5%, TN 57,79±0,7%, dan TP 72,28±0,5%. Dari hasil tersebut dapat dilihat bahwa efisiensi penyisihan terbesar untuk reaktor anoksik adalah penyisihan nitrat.  Kinetika penyisihan yang terpilih adalah kinetika orde pertama dengan k1 adalah 0,249 ±0,02/jam. Nilai kinetika yang didapatkan telah mendekati efisiensi penyisihan per jam sebelum steady state dibandingkan dua model lainnya.  </dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID">Penelitian, Pengabdian kepada Masyarakat dan Inovasi ITB</dc:contributor>
	<dc:date>2025-02-04</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/12430</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v12i3.315-326</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 12, No 3 (2024); 315-326</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/12430/3858</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/1046</identifier>
				<datestamp>2023-03-01T06:34:31Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Identifikasi Resiko pada Rencana Pengamanan Air Minum (RPAM) Operator untuk Sumber Air Permukaan di PDAM Tirta Raharja Kabupaten Bandung</dc:title>
	<dc:creator>ADIYANTI, DEWI NUR</dc:creator>
	<dc:creator>S.DJ,, RACHMAWATI</dc:creator>
	<dc:creator>HANDAYANI, DYAH ASRI</dc:creator>
	<dc:subject xml:lang="id-ID"></dc:subject>
	<dc:description xml:lang="id-ID">ABSTRAKUU No. 11 Tahun 1974 dan target RPJMN 2015-2019, mengharuskan PDAM Tirta Raharja Kabupaten Bandung untuk menyuplai air minum yang sehat dan berkualitas. Hal ini terkendala oleh penurunan kualitas air permukaan akibat banyaknya pencemar, penurunan kuantitas air akibat musim kemarau dan perebutan air, penurunan kontinuitas air akibat debit air yang didapat semakin berkurang, dan penuruan keterjangkauan pembelian air bagi pelanggan akibat biaya operasi yang semakin meningkat. RPAM dapat menjadi solusi untuk mengamankan air minum dari sumber hingga pelanggan melalui analisa dan manajemen resiko dari hasil inventarisasi dokumen, survei, dan diskusi. Identifikasi resiko pada dokumen RPAM merupakan tahapan untuk menentukan besar skor resiko/prioritas terhadap kejadian bahaya pada SPAM. Resiko yang memiliki prioritas tinggi ialah penurunan kualitas-kuantitas-kontinuitas air baku, peningkatan penggunaan koagulan dan pencucian filter, proses drain tidak efektif, produksi terhenti akibat tidak tersedianya listrik cadangan, penurunan kualitas dan kuantitas air minum.Kata kunci: RPAM, PDAM Tirta Raharja Kabupaten Bandung, Air Permukaan, Besar Skor Resiko</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2016-09-08</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/1046</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v4i2.%p</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 4, No 2 (2016); 86-96</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/1046/1270</dc:relation>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/3767</identifier>
				<datestamp>2022-11-14T05:46:10Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Perencanaan Sistem Penyaluran Air Limbah Domestik Kecamatan  Tanah Sareal Kota Bogor</dc:title>
	<dc:creator>SIREGAR, KHAIRIL IRFAN</dc:creator>
	<dc:creator>HARTATI, ETIH</dc:creator>
	<dc:creator>HALOMOAN, NICO</dc:creator>
	<dc:subject xml:lang="id-ID"></dc:subject>
	<dc:description xml:lang="id-ID">AbstrakÂ Kecamatan Tanah Sareal merupakan Kecamatan terbesar ketiga di Kota Bogor dengan luas wilayah Kecamatan sebesar 1.884 Ha. Jumlah penduduk tahun 2016 di Kecamatan Tanah Sareal sebesar 226.906 jiwa. Terdapat 6 Kelurahan di Kecamatan Tanah Sareal berstatus risiko tinggi sanitasi. Kecamatan Tanah Sareal akan diproyeksikan menjadi Pusat Kota baru di Kota Bogor. Berdasarkan RTRW Kota Bogor 2011-2031 akan direncanakan sistem penyaluran air limbah domestik dengan sistem offsite sanitasi dengan lokasi IPAL di Kecamatan Tanah Sareal. Sehingga dibutuhkan sistem penyaluran air limbah domestik Kecamatan Tanah Sareal. Tujuan dari perencanaan ini adalah merencanakan jaringan pipa indukÂ  dan lateral sistem penyaluran air limbah domestik di Kecamatan Tanah Sareal. Langkah-langkah yang dilakukan dalam perencanaan ini, yaitu proyeksi penduduk, perencanaan jalur, perhitungan debit, perhitungan dimensi pipa, dan perhitungan Rencana Anggaran Biaya. Rancangan umum sistem penyaluran air limbah domestik mengacu pada Master Plan Air Limbah Kota Bogor dengan Periode desain 20 tahun. Jalur perencanaan sistem penyaluran air limbah di Kecamatan Tanah Sareal memiliki total panjang saluran 7.418 m, sistem pengaliran secara gravitasi, diameter pipa induk antara (600-1000) mm, debit minimum sebesar 1,13 m3/detik, waktu pengaliran sampai IPAL 5,88 jam, debit 1.403Â  L/detik, Manhole yang digunakan sebanyak 424 unit, dan Rencana Anggaran Biaya sebesar Rp. 34.688.256.575,55.Kata kunci: Kecamatan Tanah Sareal, Limbah Domestik, Sistem Offsite Sanitasi.AbstractTanah Sareal Sub-district is the third largest sub district in Bogor City with the area of District is 1,884 Ha. Based on RTRW Kota Bogor 2011-2031 will be built sanitation offsite system with Waste Water Treatment Plan (WWTP) location in Kecamatan Tanah Sareal. The purpose of this plan is to plan the pipeline network and lateral domestic waste water sewerage system in Tanah Sareal Sub-district. The steps taken in this planning are population projection, pipeline planning, water discharge calculation, pipe dimension calculation, and calculation of Budget Plan. The general design of domestic waste water sewerage system refers to Bogor City Wastewater Master Plan. The sewerage system in Tanah Sareal Sub-district has a total length of 7.418 m channel, gravity sewerage system, pipe diameter between (600-1000) mm, minimum discharge of 1.13 m3 / sec, the flow time up to WWTP 5.88 Hour,Â  flow discharge 1,403 L/sec, Manhole used 424 units, and Budget Plan Rp. 34.688.256.575,55.Keywords: Tanah Sareal Sub-district, Domestic Wastewater, Sanitation Offsite System,. </dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2020-03-03</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/3767</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v8i1.27-37</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 8, No 1 (2020); 26-35</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/3767/2295</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/8543</identifier>
				<datestamp>2023-07-03T03:06:37Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">EMISI GAS RUMAH KACA DARI PENGELOLAAN SAMPAH DI JAKARTA, INDONESIA</dc:title>
	<dc:creator>Sekarsari, Nindi</dc:creator>
	<dc:creator>Kristanto, Gabriel Andari</dc:creator>
	<dc:creator>Dahlan, Astryd Viandila</dc:creator>
	<dc:subject xml:lang="id-ID">gas rumah kaca;IGES;Indonesia;Jakarta;sampah perkotaan</dc:subject>
	<dc:description xml:lang="id-ID">Pengelolaan sampah perkotaan yang masih bertumpu pada pembuangan akhir di TPA (landfill) merupakan masalah lingkungan yang serius di Jakarta, Indonesia. Sistem pengelolaan sampah perkotaan berkontribusi terhadap emisi gas rumah kaca (GRK) pada semua tahapan pengelolaannya. Studi ini bertujuan memberikan gambaran umum tentang praktik pengelolaan sampah di Jakarta dan mengkaji kontribusi pengelolaan sampah perkotaan terhadap emisi GRK. Pada akhirnya dapat diketahui hotspot emisi GRK dalam tahapan pengelolaan sampah perkotaan dan lokasi spasial penyebaran emisi GRK di wilayah Jakarta. Perhitungan emisi GRK dilakukan pada setiap kota dan kabupaten administrasi pada tahun 2022 menggunakan Emission Quantification Tool (EQT) version II oleh Institute for Global Environmental Strategies (IGES). Hasil studi mengestimasi emisi GRK dari pengelolaan sampah perkotaan Jakarta pada tahun 2022 sebesar 1.516,60 ribu ton CO2-eq/tahun dengan kontributor terbesar berada di Kota Administrasi Jakarta Barat sebesar 433,4 ribu ton CO2-eq/tahun dan yang terkecil berada di Kabupaten Administrasi Kepulauan Seribu sebesar 2,7 ribu ton CO2-eq/tahun. Secara total, emisi GRK dari pembuangan akhir di TPST Bantar Gebang (2.034,5 ribu ton CO2-eq/tahun) memberikan kontribusi emisi terbesar di wilayah Jakarta. Jumlah penduduk, rendahnya praktik pengurangan sampah dan pengolahan sampah mempengaruhi besaran emisi GRK yang dihasilkan.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2023-06-15</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/8543</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v11i1.71-82</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 11, No 1 (2023); 71-82</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/8543/3326</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/12241</identifier>
				<datestamp>2024-10-21T23:32:52Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">KELIMPAHAN DAN KARAKTERISTIK MIKROPLASTIK DI UDARA AMBIEN TEMPAT PEMROSESAN AKHIR (TPA) PIYUNGAN, YOGYAKARTA</dc:title>
	<dc:creator>Ardiyanta, Iwan</dc:creator>
	<dc:creator>Rahmawati, Suphia</dc:creator>
	<dc:creator>Abdull, Norhidayah Binti</dc:creator>
	<dc:creator>Jannah, Baiq Raudatul</dc:creator>
	<dc:creator>Pradana, Nasrul Fajar</dc:creator>
	<dc:subject xml:lang="id-ID"></dc:subject>
	<dc:description xml:lang="id-ID">AbstrakMikroplastik adalah partikel berukuran kurang dari 5 mm yang ditemukan di berbagai media, mulai dari tanah, air, hingga udara. Penelitian tentang mikroplastik banyak berfokus pada media air dan tanah, sedangkan penelitian tentang mikroplastik di udara  Indonesia masih jarang. Penelitian ini bertujuan untuk mengidentifikasi dan menganalisis keberadaan mikroplastik di udara ambien sekitar Tempat Pembuangan Akhir (TPA) Piyungan, Yogyakarta. Sampel udara diambil menggunakan High Volume Air Sampler (HVAS) selama 24 jam dan diperiksa secara visual menggunakan mikroskop, Scaning Electron Microscope (SEM) kemudaian dianalisis dengan Spektroskopi Infra merah Transformasi Fourier (FTIR). Hasil penelitian menunjukkan adanya kelimpahan partikel mikroplastik dalam bentuk fragmen, film, dan fiber dengan berbagai warna terutama warna hitam. Mikroplatik ditemukan dalam semua partikel yang dianalisa, termasuk pada Total Suspended Particulate (TSP), Particulate Matter 10 µm (PM10) dan Particulate Matter 2,5 µm (PM2,5). Penelitian ini menunjukkan kelimpahan jenis, warna dan potensi dugaan keberadaan mikroplastik dalam ukuran partikel yang lebih halus sehingga dapat menjadi dasar penelitian lebih lanjut mengenai mikroplastik yang dapat terhirup dan berdampak pada kesehatan.Kata kunci : mikroplastik, sampah padat, partikulat di udara</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2024-10-22</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/12241</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v12i2.145-157</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 12, No 2 (2024); 145-157</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/12241/3732</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/14466</identifier>
				<datestamp>2026-04-03T02:44:45Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">SIMULASI KUALITAS AIR SUNGAI X MENGGUNAKAN MODEL QUAL2Kw</dc:title>
	<dc:creator>Tedjakusuma, Teddy</dc:creator>
	<dc:creator>Maulida, Faliha Alya</dc:creator>
	<dc:creator>Hidayat, Syarif</dc:creator>
	<dc:subject xml:lang="id-ID">Indek Pencemar; Simulasi Sungai; Pencemaran Sungai</dc:subject>
	<dc:description xml:lang="id-ID">Sungai merupakan sumber daya air yang sangat penting bagi kehidupan manusia. Namun, pembuangan limbah cair ke sungai menyebabkan beban pencemar terutama materi organik di sungai terus meningkat. Berdasarkan perhitungan indeks pencemaran, diketahui bahwa seluruh sungai di DKI Jakarta masuk ke dalam kategori tercemar berat. Setelah dilakukan pembobotan, Sungai Ciliwung (segmen 5) dianggap memenuhi kriteria sungai yang akan menjadi objek penelitian. Kalibrasi model dilakukan dengan melakukan trial and error pada berbagai parameter kinetik model. Nilai RMSPE untuk kalibrasi model BOD yakni sebesar 2,45% dan untuk model DO sebesar 3,84%. Berdasarkan analisis sensitivitas yang telah dilakukan, parameter kinetik model yang paling memengaruhi hasil pemodelan untuk parameter BOD adalah slow CBOD hydrolysis rate dan detritus dissolution rate, sedangkan untuk parameter DO adalah fast CBOD oxidation rate. Hasil simulasi menunjukkan bahwa untuk parameter DO pada seluruh skenario, kualitas air hanya memenuhi baku mutu Kelas 4 sedangkan pada hulu memenuhi baku mutu Kelas 3. Sementara itu, untuk parameter BOD pada skenario 1, 3, dan 4, kualitas air hanya memenuhi baku mutu Kelas 4, sedangkan pada hulu memenuhi baku mutu Kelas 3. Khusus untuk skenario 2, kualitas air memenuhi baku mutu Kelas 3 di seluruh titik. Hasil perhitungan beban pencemaran BOD menunjukkan bahwa untuk seluruh skenario, beban pencemaran BOD aktual lebih tinggi dibandingkan dengan beban pencemaran BOD maksimum. Untuk dapat memenuhi jumlah yang diperbolehkan, beban pencemaran BOD perlu diturunkan sebesar 30%-70%. Berdasarkan simulasi kualitas air yang dilakukan pada skenario 3 dan 4, dapat disimpulkan bahwa beban pencemaran terutama dari sumber domestik memberikan pengaruh yang signifikan pada konsentrasi BOD dan DO di dalam air sehingga diperlukan pengelolaan air limbah domestik untuk dapat menurunkan beban pencemaran tersebut.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2026-03-05</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/14466</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 13, No 2 (2025); 163-175</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/14466/4321</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/2704</identifier>
				<datestamp>2021-03-02T16:41:55Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">IDENTIFIKASI TEKNOLOGI PENGOLAHAN SAMPAH PASAR SEDERHANA</dc:title>
	<dc:creator>Wicaksono, Aditya</dc:creator>
	<dc:creator>PRATAMA, YULIANTI</dc:creator>
	<dc:creator>HALOMOAN, NICO</dc:creator>
	<dc:subject xml:lang="id-ID"></dc:subject>
	<dc:description xml:lang="id-ID">ABSTRAK Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â  Â Pasar Sederhana merupakan salah satu pasar yang berada di Kecamatan Sukajadi dimana sangat dekat dengan pemukiman dan berpotensi menimbulkan masalah di lingkungan sekitar ketikaÂ tidak ditangani dengan benar. Mengacu pada undang- Undang No 18 Tahun 2008 tentang Pengelolaan Sampah, salah satu cara yang efektif dalam mengurangi jumlah timbulan sampah dari sumbernya di antaranya berupa memanfaatkan kembali sampah dengan teknologi yang dapat membuat sampah memiliki nilai baik ekonomi maupun fungsi. Maksud dari studi ini adalah mengidentifikasi komposisi, timbulan dan karakteristik sampah di lokasi penelitian, untuk menentukan teknologi pengolahan yang tepat sehingga mengurangi jumlah sampah yang diangkut ke TPA. Â Pengumpulan data dilakukan dengan cara melakukan obesrvasi, wawancara dan pengukuran dilapangan. Hasil observasi dan wawancara, Pasar Sederhana melakukan pengelolaan dimulai dari pewadahan sampah sampai pemindahan sampah dari wadah kedalam bak kontainer, untuk pengangkutan dilakukan oleh pihak PD.Kebersihan. Sampah yang dihasilkan didominasi oleh sampah organik sebesar 84%, satuan timbulan sampah sebesar 0,609 Kg/m2/hari dan densitas sebesar 0,178 kg/l. Dari pengukuran karakteristik didapat kadar air sebesar 77%, karbon organik 43,55%, NTK 0,18% dan rasio C/N 242 Berdasarkan pengukuran, sampah pasar sederhana memiliki potensi dimanfaatkan baik sebagai bahan baku pengomposan atau bahan baku biodigester. Tetapi dibutuhkan pre-treatment agar sampah pasar sederhana dapat dimanfaatkan sebagai bahan baku pengomposan ataupun biodigester.Â Kata Kunci : pengolahan sampah,Â  pengukuran , Pasar Sederhana.Â  </dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2019-02-22</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/2704</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v7i1.47-55</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 7, No 1 (2019); 47-55</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/2704/1991</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/7211</identifier>
				<datestamp>2022-12-17T17:36:16Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">PERBEDAAN LAJU ALIR DAN VOLUME ADSORBEN KULIT PISANG KEPOK TEHADAP PENURUNAN LOGAM TIMBAL DALAM REAKTOR KONTINYU</dc:title>
	<dc:creator>Nisak, Khoiriyatun</dc:creator>
	<dc:creator>Setyowati, RR Diah Nugraheni</dc:creator>
	<dc:creator>Suprayogi, Dedy</dc:creator>
	<dc:subject xml:lang="id-ID">Adsorpsi;kulit pisang kepok;timbal;anova</dc:subject>
	<dc:description xml:lang="id-ID">Meningkatnya kegiatan industri dapat menimbulkan dampak negatif yang dapat membahayakan lingkungan seperti terjadinya pencemaran akibat adanya logam berat pada air. Salah satu metode untuk menurunkan kadar logam berat pada air yakni dengan adsorpsi. Proses adsorpsi dapat dilakukan menggunakan adsorben sebagai zat penyerap dengan memanfaatkan limbah organik. Tujuan dari penelitian ini adalah untuk mengetahui besarnya konsentrasi logam timbal yang terserap dalam proses adsorpsi menggunakan adsorben limbah kulit pisang kepok dalam reaktor kontinyu dan menganalisa pengaruh variasi yang digunakan pada proses adsorpsi. Penelitian ini dilakukan secara eksperimental dengan menggunakan variasi laju alir (2,4, dan 6 ml/mnt) dan variasi volume adsorben (15, 20, dan 25 cm). Data hasil adsorpsi akan diolah menggunakan SPSS untuk dilakukan uji statistika menggunakan two way anova. Prasyarat data untuk uji two way anova adalah data harus berdistribusi secara normal dan bersifat homogen. Hasil dari penelitian Â menunjukkan bahwa proses adsorpsi menggunakan adsorben limbah kulit pisang kepok dapat menyerap timbal sebesar 7,118 mg/l yakni dari kadar awal sebesar 7,401 mg/l menjadi 0,282 mg/l dengan tingkat efisiensi sebesar 94,5% dan terdapat pengaruh yang signifikan terhadap variasi laju alir pada proses adsorpsi.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2022-11-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/7211</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v10i3.232-241</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 10, No 3 (2022); 232-241</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/7211/3091</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/10580</identifier>
				<datestamp>2024-07-16T07:42:26Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">EVALUASI SISTEM PENGELOLAAN LIMBAH MEDIS PADAT DI RUMAH SAKIT UMUM DAERAH UNDATA KOTA PALU</dc:title>
	<dc:creator>Palita, Fadel Banna</dc:creator>
	<dc:creator>Purnaweni, Hartuti</dc:creator>
	<dc:creator>Luqman, Yanuar</dc:creator>
	<dc:subject xml:lang="id-ID">Evaluasi; Limbah; Rumah Sakit; Padat</dc:subject>
	<dc:description xml:lang="id-ID">Limbah merupakan permasalahan lingkungan yang masih belum sepenuhnya teratasi dengan baik padahal dampak yang dihasilkan berpengaruh besar terhadap pencemaran lingkungan, terlebih khusus limbah medis padat. Penelitian ini bertujuan untuk mengkaji karakteristik limbah medis padat di RSUD Undata berdasarkan sumber dan jenisnya, menghitung jumlah timbulan berat rata-rata limbah medis padat yang terproduksi setiap harinya, serta mengevaluasi sistem pengelolaan limbah medis padat dengan moda pemilahan, pewadahan, pengumpulan serta pengangkutan sesuai dengan kriteria Permen LHK No 56 Tahun 2015 serta Permenkes Nomor 2 Tahun 2023. Penelitian ini menggunakan pendekatan kualitatif dengan jenis penelitian deskriptif. Penelitian ini dilaksanakan pada bulan Agustusâ€“September tahun 2023. Teknik pengambilan sampel pada penelitian ini menggunakan Purposive Sampling. Berdasarkan hasil penelitian didapatkan bahwa setiap harinya RSUD Undata Palu menghasilkan limbah domestik sebanyak Â±270 kg/hari. Hasil Evaluasi pada sistem pengelolaan limbah medis padat di RSUD Undata Palu menunjukkan bahwa pada dasarnya sudah cukup efektif namun belum maksimal, karena pada proses penyimpanan menunjukkan ketidak sesuaian dengan pedoman pengelolaan limbah medis oleh Kemenkes Nomor 2 tahun 2023 yaitu penyimpanan di TPS yang seharusnya tidak boleh lebih dari 2x24 jam. Hal ini menyebabkan banyaknya timbulan limbah padat pada TPS sehingga TPS menjadi penuh dan berbahaya lingkungan.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2024-07-16</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/10580</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v12i1.51-61</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 12, No 1 (2024); 51-61</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/10580/3676</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/680</identifier>
				<datestamp>2023-04-07T09:46:20Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Perbandingan Potensi Berat dan Volume Lumpur  yang Dihasilkan oleh IPA Badak Singa  PDAM Tirtawening Kota Bandung  Menggunakan Data Sekunder dan Primer</dc:title>
	<dc:creator>Pratiwi, Riska</dc:creator>
	<dc:creator>S.DJ, Rachmawati</dc:creator>
	<dc:creator>P, Kancitra</dc:creator>
	<dc:subject xml:lang="id-ID"></dc:subject>
	<dc:description xml:lang="id-ID">AbstrakMerencanakan sistem pengolahan lumpur, memerlukan kuantitas lumpur sebagai dasar perencanaan. Kuantitas lumpur dapat dihitung menggunakan data sekunder maupun primer. Perbandingan hasil perhitungan dengan menggunakan kedua data tersebut, diharapkan dapat diperoleh potensi berat dan volume lumpur yang mempresentasikan kondisi sebenarnya, sehingga dapat dijadikan sebagai dasar perencanaan sistem pengolahan lumpur yang efektif. Kedua jenis data tersebut memiliki kelebihan. Kelebihan data sekunder, informasi yang diperoleh merupakan data deret waktu sehingga lebih representatif, sedangkan data primer merupakan gambaran karakteristik sebenarnya di lapangan. Sehingga kedua data tersebut akan digunakan untuk perhitungan kuantitas lumpur. Data sekunder yang digunakan terdiri dari kapasitas air baku yang diolah, kekeruhan air baku, serta dosis PAC yang ditambahkan, sedangkan data primer yang akan digunakan adalah besarnya persen padatan solid dan specific gravity pada lumpur. Potensi berat lumpur pada kondisi rata-rata sebesar 19.602,12 kg/hari dengan volume sebesar 515,41 m3/hari, sedangkan pada kondisi maksimum berat lumpur sebesar 46.306,03 kg/hari dengan volume 1.217,56 m3/hari.Â Kata kunci: Berat Lumpur, Volume Lumpur, Data Sekunder, Data Primer. </dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2015-03-16</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/680</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v3i1.%p</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 3, No 1 (2015); 30-40</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/680/880</dc:relation>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/3133</identifier>
				<datestamp>2021-03-02T16:37:56Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Perencanaan Sistem Instalasi Plambing Air Bersih Gedung Olifant School</dc:title>
	<dc:creator>SAFIYANTI, ANNISA DWI</dc:creator>
	<dc:creator>PRATAMA, YULIANTI</dc:creator>
	<dc:creator>NURPRABOWO, ANINDITO</dc:creator>
	<dc:subject xml:lang="id-ID"></dc:subject>
	<dc:description xml:lang="id-ID">AbstrakGedung Olifant School memiliki luas bangunan 10.512 m2 dan terdiri dari 6 lantai merupakan sekolah bertaraf internasional yang berada di kota Yogyakarta. Perencanaan sistem instalasi plambing gedung Olifant School meliputi penyediaan air bersih dingin dan air bersih panas yang memiliki peranan sangat penting dalam pemenuhan aspek sarana dan prasarana yang menunjang sanitasi untuk mendukung proses pemberlajaran pengguna gedung. Perhitungan kebutuhan air dan diameter pipa air bersih dingin dan panas mengacu pada SNI 03-6481-2000 dan SNI 03-7065-2005. Hasil yang diperoleh untuk total kebutuhan air bersih adalah 51,77 m3/hari dimana kebutuhan air bersih dingin adalah sebesar 27,95 m3/hari, kebutuhan balancing tank sebesar 14,22 m3/haridan kebutuhan air bersih panas sebesar 9,6 m3/hari. Jenis pipa air bersih dingin dan panas yang digunakan adalah pipa PPR (Poly Propylene Random) dengan rentang diameter pipa air bersih dingin 15-100 mm dan air bersih panas 15-40 mm.Kata kunci: plambing, air bersih dingin, air bersih panas, diameter pipa</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2019-09-03</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/3133</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v6i2.%p</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 6, No 2 (2018)</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/3133/2003</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/6076</identifier>
				<datestamp>2023-10-30T19:27:41Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">PENGARUH TEGANGAN DAN WAKTU PADA PENGOLAHAN LINDI METODE ELEKTROKOAGULASI-ADSORPSI ZEOLIT</dc:title>
	<dc:creator>Putri, Rosa Amalia</dc:creator>
	<dc:creator>Purnama, Herry</dc:creator>
	<dc:subject xml:lang="id-ID">Air lindi; elektrokoagulasi; adsorpsi zeolit; tegangan; waktu</dc:subject>
	<dc:description xml:lang="id-ID">Air lindi dapat menjadi pencemar lingkungan jika dibuang begitu saja tanpa adanya pengolahan. Hal ini karena lindi mengandung zat-zat kimia beracun, senyawa organik serta konstituen lainnya yang terlarut dan tersuspensi di dalam tanah. Sifat utama lindi adalah BOD, COD, rasio BOD/COD, padatan tersuspensi, pH, amonia-nitrogen, dan logam berat. Kandungan COD, TSS, dan pH pada air lindi harus memenuhi syarat baku mutu yang telah ditetapkan agar aman ketika dibuang ke lingkungan. Penelitian ini bertujuan untuk mengetahui pengaruh tegangan dan waktu terhadap nilai COD, TSS, dan pH pada air lindi menggunakan metode elektrokoagulasi-adsorpsi zeolit. Penelitian akan dikembangkan dengan variasi tegangan (10, 20, dan 30 volt) dan waktu proses ( 30, 60 , dan 90 menit). Setelah proses elektrokoagulasi, dilanjutkan adsorpsi menggunakan adsorben zeolit dengan massa 30 gram dan waktu adsorpsi 2 jam. Hasil percobaan menunjukkan bahwa kondisi yang optimum diperoleh pada variasi tegangan 30 volt dan waktu proses 90 menit dengan efisiensi penurunan COD sebesar 98.6%, efisiensi penurunan TSS sebesar 99.86%, dan perolehan pH sebesar 9,4.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID">Direktorat Sumber Daya Ditjen Diktiristek Kemedikbudristek</dc:contributor>
	<dc:date>2022-06-08</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/6076</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v10i2.135-144</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 10, No 2 (2022); 135-144</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/6076/2936</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/9348</identifier>
				<datestamp>2024-01-19T00:42:06Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">EVALUASI PENGELOLAAN LIMBAH BAHAN BERBAHARA BERACUN (B3) PADA BENGKEL DI WILAYAH JAKARTA</dc:title>
	<dc:creator>Dahlan, Astryd Viandila</dc:creator>
	<dc:creator>Mursidik, Setyo Sarwanto</dc:creator>
	<dc:creator>Rinjani, Cholisa Amalia Putri</dc:creator>
	<dc:creator>Luthfi, Muhammad Rifaldi</dc:creator>
	<dc:creator>Nurlaily, Salma</dc:creator>
	<dc:subject xml:lang="id-ID">limbah B3, limbah bengkel, Indonesia, Jakarta</dc:subject>
	<dc:description xml:lang="id-ID">Â AbstrakBengkel kendaraan bermotor sebagai penyedia jasa perbaikan maupun perawatan kendaraan bermotor berpotensi menimbulkan limbah berbahaya dan beracun (B3). Banyaknya jumlah dan variasi perawatan kendaraan ini tentu berpengaruh terhadap total jumlah limbah yang ditimbulkan oleh bengkel. Oleh karena itu, evaluasi pengelolaan limbah berbahaya di bengkel kendaraan bermotor sangat penting. Penelitian ini bertujuan untuk mengidentifikasi dan mengkarakterisasi komponen limbah berbahaya, mengamati praktik pengelolaan saat ini, dan mengusulkan metode pengelolaan limbah yang tepat. Enam bengkel sepeda motor dan tiga bengkel mobil di Jakarta menjadi sampel pada penelitian ini. Jenis limbah berbahaya (B3) yang terindentifikasi pada bengkel kendaraan bermotor meliputi kain bekas, minyak bekas, botol limbah, botol pendingin bekas, dan suku cadang bekas, dengan berat total berkisar antara 0,54 kg/unit/hari hingga 0,83 kg/unit/hari. Namun, praktik pengelolaan limbah berbahaya dan beracun di bengkel-bengkel ini belum sepenuhnya sesuai dengan Peraturan Menteri Lingkungan Hidup No. 6 tahun 2021. Tindakan rekomendasi perbaikan diperlukan untuk mengatasi masalah ini dan melindungi kesehatan manusia serta lingkungan.Kata kunci: limbah B3, limbah bengkel, Indonesia, JakartaAbstractVehicle workshops as providers of vehicle repair and maintenance services have the potential to generate hazardous and toxic waste. The large number and variety of vehicle maintenance certainly influence the total waste generated by the workshops. Therefore, assessing hazardous waste management in vehicle workshops is vital. The study aims to identify and characterize hazardous waste components, observe current management practices, and propose proper waste management methods. Six motorcycle and three car repair shops in Jakarta were examined. Hazardous waste types found in all vehicle workshops include used cloth, waste oil, bottles, coolant bottles, and used auto parts, with average waste generated ranging from 0.54 kg/unit/day to 0.83 kg/unit/day. Despite the findings, it is evident that the hazardous and toxic waste management practices in these repair shops do not fully comply with The Minister of Environment and Forestry Regulation No. 6 of 2021. Urgent action is needed to address these issues and safeguard human health and the environment.Keywords: Hazardous waste, waste vehicle workshops, Indonesia, Jakarta.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2024-01-18</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/9348</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v11i3.234-245</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 11, No 3 (2023); 234-245</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/9348/3549</dc:relation>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/downloadSuppFile/9348/768</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/13398</identifier>
				<datestamp>2026-02-22T05:50:18Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">KARBON AKTIF KULIT SINGKONG (Manihot utilissima) UNTUK PENYISIHAN FOSFAT AIR LIMBAH LAUNDRY ARTIFISIAL</dc:title>
	<dc:creator>Saud, Muhamad Nur Ibnu Luthfi</dc:creator>
	<dc:creator>Amukti, Muhammad Yoga</dc:creator>
	<dc:creator>Hudayarizka, Riza</dc:creator>
	<dc:creator>Anifah, Eka Masrifatus</dc:creator>
	<dc:subject xml:lang="id-ID">Adsorpsi; Fosfat; Karbon Aktif; Kulit Singkong; Limbah Laundry</dc:subject>
	<dc:description xml:lang="id-ID">Konsentrasi fosfat yang tinggi pada air limbah laundry perlu diolah karena dapat menyebabkan eutrofikasi. Eutrofikasi di badan air dapat berdampak langsung bagi makhluk hidup. Selain itu, banyaknya pemanfaatan singkong sebagai bahan makanan berpotensi menghasilkan limbah biomassa seperti kulit singkong. Limbah kulit singkong mengandung karbon dan selulosa yang baik untuk dijadikan karbon aktif. Salah satu metode yang efektif, efisien, dan murah untuk menurunkan konsentrasi fosfat adalah adsorpsi menggunakan karbon aktif. Penelitian ini bertujuan menganalisis pengaruh dosis dan waktu kontak untuk menurunkan fosfat dalam air limbah laundry artificial serta menentukan kinetika adsorpsi yang terjadi. Penelitian dilakukan secara batch menggunakan variasi dosis adsorben 2-10 gr/L dan waktu kontak 15-120 menit dengan kecepatan pengadukan 110 RPM. Karbon aktif dihasilkan melalui proses karbonisasi kulit singkong dan aktivasi dengan NaOH 0,3 N. Hasil penyisihan optimum sebesar 8% didapatkan pada dosis adsorben 4 gr/L dengan waktu kontak 60 menit. Kinetika adsorpsi yang didapatkan termasuk model Orde Dua Semu.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2025-10-28</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/13398</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v13i1.25-36</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 13, No 1 (2025); 25-36</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/13398/4102</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/1206</identifier>
				<datestamp>2022-07-21T15:34:17Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Kajian Desain Cerobong Asap Terhadap Emisi PM10 dan SO2 Akibat Pembakaran Batubara di PLTU PT. X</dc:title>
	<dc:creator>Ramadhan, Winona Maheswari</dc:creator>
	<dc:creator>Soemirat, Juli</dc:creator>
	<dc:creator>Taroepratjeka, Dyah Asri Handayani</dc:creator>
	<dc:subject xml:lang="id-ID"></dc:subject>
	<dc:description xml:lang="id-ID">PLTU berbahan bakar batubara PT. X direncanakan untuk memenuhi kebutuhan listrik pada proses produksi pelet plastik, kemasan gelas plastik air minum dan karung plastik. Kapasitas PLTU yang akan dibangun adalah 2 x 6 MW. Polutan utama akibat kegiatan ini yaitu PM10 yang dapat menyebabkan penurunan fungsi paru-paru dan gas SO2 yang dapat menyebabkan penyakit pernapasan. PT. X menggunakan ESP dengan efektifitas 95% untuk mengendalikan emisi PM10. Penelitian ini dilakukan untuk mengkaji desain cerobong dan mengkaji kesesuaian penggunaan electrostatic precipitator (ESP) pada parameter PM10. Prediksi laju emisi PM10 dan SO2 setelah PLTU beroperasi dilakukan menggunakan faktor emisi. Pemodelan dispersi udara menggunakan Model Gaussian. Desain cerobong PLTU memiliki tinggi 40,5 m, diameter 1,8 m, kecepatan alir gas buang 10 m/dtk dengan konsumsi batubara 280 ton/h. Hasil penelitian menunjukkan bahwa desain cerobong PLTU sudah optimal. Dengan desain demikian, konsentrasi emisi SO2 (557,3  ) memenuhi baku mutu PERMEN LH No. 21 Tahun 2008 (750  ) dan konsentrasi udara ambien PM10 dan SO2 memenuhi baku mutu PP No. 41 Tahun 1999 di lokasi uji sekitar PLTU. Oleh sebab itu tidak diperlukan alat pengendali polutan SO2. Parameter PM10 tidak diatur dalam baku mutu udara emisi. Penggunaan cyclone jauh lebih efisien dan ekonomis dibandingkan dengan ESP sebagai alat pengendali partikulat.Kata kunci: Model Gaussian, Faktor Emisi, Pembakaran Batubara, Pemodelan Udara</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2017-04-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/1206</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v5i1.%p</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 5, No 1 (2017)</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/1206/1411</dc:relation>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/4451</identifier>
				<datestamp>2022-03-06T18:22:34Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Desain Enclosure Akustik Sebagai Mitigasi Polusi Kebisingan di Pembangkit Listrik Mikrohidro Dago Bengkok Bandung</dc:title>
	<dc:creator>Berliansyah, Seprijal</dc:creator>
	<dc:creator>Permadi, Didin Agustian</dc:creator>
	<dc:subject xml:lang="id-ID"></dc:subject>
	<dc:description xml:lang="id-ID">AbstrakKebisingan industri merupakan gangguan suara yang diakibatkan terutama berasal dari operasional mesin, gangguan ini dapat mengganggu kesehatan dan performansi pekerja industri tersebut. Dari hasil pengukuran lapangan didapatkan nilai tingkat kebising 8 jam di ruang turbin-generator sebesar 92-99 dBA.. Dari perencanaan yang dilakukan untuk desain enclosure didapatkan spesifikasi enclosure yaitu menggunakan material plywood dengan ukuran 16 m x 7 m x 2,5 m, diberi dua buah pintu akses ukuran 2 m x 1 m menggunakan material plywood, didapatkan efektifitas penurunan tingkat kebisingan sebesar 38,07 dBA, sehingga didapatkan penurunan tingkat kebisingan setelah penggunaan enclosure di area turbin-generator menjadi 54-56 dBA. Total anggaran biaya yang dibutuhkan untuk membangun enclosure sebesar Rp 135.721.378,00.Kata kunci : kebisingan; enclosure; turbin-generatorÂ AbstractIndustrial noise is a sound disturbance that is caused mainly from machine operations, this disturbance can interfere with the health and performance of the industrial workers. From the results of field measurements, the 8 hours noise level in the turbine-generator room is 92-99 dBA. By applying the source-medium-receiver concept approach, it is known that one of the most effective techniques for controlling noise is by using an acoustic enclosure. From the planning carried out for the enclosure design, specifications are obtained, namely using plywood material with a size of 16 m x 7 m x 2.5 m, the effectiveness of reducing noise levels is 38.07 dBA, resulting in a reduction in noise levels after using the enclosure in the turbine-generator area becomes 54-56 dBA. The total budget needed to build the enclosure is IDR 135,721,378Keywords : noise; enclosure; turbine-generator</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2021-06-04</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/4451</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v10i1.57-66</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 10, No 1 (2022); 57-66</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/4451/2571</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/8847</identifier>
				<datestamp>2023-10-31T02:25:10Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">UJI TOKSISITAS AIR LINDI (LEACHATE)  TPA BATU LAYANG,  KOTA PONTIANAK  TERHADAP IKAN NILA (OREOCHROMIS NILOTICUS) DENGAN METODE UJI RENEWAL TEST</dc:title>
	<dc:creator>Maulidia, Bela</dc:creator>
	<dc:creator>Pramadita, Suci</dc:creator>
	<dc:creator>Jumiati, J</dc:creator>
	<dc:subject xml:lang="id-ID">Ikan nila (Oreocromis niloticus), LC50, Renewal Test, Uji Toksisitas.</dc:subject>
	<dc:description xml:lang="id-ID">AbstrakAir lindi dapat mencemari lingkungan sekitar Tempat Pemrosesan Akhir (TPA) apabila tidak diolah dengan baik, sehingga dapat berpotensi bahaya terhadap makhluk hidup diperairan. Instalasi Pengolahan Lindi dapat mengatasi semua jenis polutan tetapi tidak tingkat toksisitasnya dan akan memperburuk masalahÂ  pencemaran, sehingga perlu dilakukan uji toksisitas dengan metode renewal test pengujian toksisitas dengan pergantian larutan uji setiap 24 jam sekali selama 96 jamdan hewan uji yang digunakan yaitu ikan nila (Oreochromis niloticus). Tujuan penelitian ini untuk mengetahui karakteristik air lindi, menghitung nilai LC50 dan menganalisa morfologi ikan nila setelah terpapar air lindi. Penelitian ini dilakukan dari pengambilan sampel limbah, aklimatisasi hewan uji, uji pendahuluan, uji toksisitas, dan analisis probit. Hasil karakteristik air lindi yaitu pH sebesar 8,3,nilai Biological Oxygen Demand (BOD) sebesar 377 mg/l, nilai Chemical Oxygen Demand (COD) sebesar 1646 mg/l, TSS sebesar 740 mg/l, N Total sebesar 794 mg/l, Merkuri &lt;0,0008 mg/l, Kadmium &lt;0,001 mg/l, hanya BOD, COD, TSS, N Total yang melewati ambang batas Peraturan Menteri Lingkungan Hidup No.59 Tahun 2016. Nilai LC50 yang didapatkan adalah 2,260% dan nilai Toxic Unit acute (TUa) adalah 44,248% termasuk kedalam kategori High Acute Toxicity. Ikan nila yang terpapar mengalami perubahan warna tubuh dan insang menjadi pucat, mengeluarkan lendir, hilangnya organ ikan bagian mata dan perubahan tingkah laku gerak.Kata kunci: Ikan nila (Oreocromis niloticus), LC50, Renewal Test, Uji Toksisitas.AbstractLeachate can contaminate the environment around the Open Dumping Landfill if it is not treated properly, so it can be potentially harmful to living things in the waters. The Leachate Treatment Plant can handle all types of pollutants but not the level of toxicity that will exacerbate the problem of pollution, so it is necessary to carry out a toxicity test using the renewal test method for toxicity by changing the test solution once every 24 hours for 96 hours. Using tilapia (Oreocromis niloticus) test animals. The purpose of this study was to determine the characteristics of leachate, calculate the LC50 value and analyze the morphology of tilapia after being exposed to leachate. This research was conducted from waste sampling, acclimatization of test animals, preliminary tests, toxicity tests, and probit analysis. The results of the leachate characteristics were pH 8.3, BOD 377 mg/l, COD 1646 mg/l, TSS 740 mg/l, Total N 794 mg/l, Mercury &lt;0.0008 mg/l, Cadmium &lt;0.001 mg/l, only BOD, COD, TSS, N Total which exceeds the threshold of PERMEN LH No. 59 of 2016. The LC50 value obtained is 2.260% and the Toxic Unit Acute (TUa) value is 44.248% included in the High Acute category Toxicity. Exposed tilapia experience changes in body color and gills to become pale, secrete mucus, loss of fish organs in the eye area, and changes in movement behavior.Keywords: Tilapia (Oreochromis niloticus), LC50, Renewal Tes, Toxicity Test.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2023-10-31</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/8847</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v11i2.162-172</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 11, No 2 (2023); 162-172</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/8847/3438</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/9513</identifier>
				<datestamp>2023-10-31T01:58:14Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/12073</identifier>
				<datestamp>2025-07-02T08:03:41Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">ANALISIS LIMBAH MATERIAL KONSTRUKSI ARSITEKTURAL PROYEK PEMBANGUNAN PLTU SULAWESI SELATAN BARRU-2</dc:title>
	<dc:creator>Arsyad, Arsyad</dc:creator>
	<dc:creator>Djurdan, Sitti Zaenab</dc:creator>
	<dc:creator>Arifin, Moch. Aris</dc:creator>
	<dc:creator>., Jamaluddin</dc:creator>
	<dc:creator>., Hamzah</dc:creator>
	<dc:creator>., Reno</dc:creator>
	<dc:creator>Yunus, Ismail</dc:creator>
	<dc:subject xml:lang="id-ID">limbah konstruksi, sisa material, persentase sisa material,material konstruksi</dc:subject>
	<dc:description xml:lang="id-ID">Penelitian bertujuan untuk mengetahui gambaran limbah material konstruksi proyek pembangunan PLTU Barru 2 – 1 x 100 MW, Dusun Bawasolo Desa Lampoko Kecamatan Balusu Kabupaten Barru Sulawesi Selatan. Metode penelitian menggunakan dokumentasi literatur dan dokumen proyek, observasi lapangan serta wawancara. Hasil penelitian menunjukkan bahwa jenis sisa material terdiri dari semen PC, pasir pasang, bata ringan, ubin warna, semen warna, dan mortar siap pakai. Persentase dari setiap material adalah  semen PC 2,2 %, bata ringan 17,8 %, pasir pasang 48,6 %, ubin warna 9,6 %, semen warna 21,3 %, mortar siap pakai 0,9 %.  Biaya sisa material tiap jenis material adalah semen PC Rp.15.390,72, bata ringan Rp. 109.000,00, pasir pasang Rp308.761,2, ubin warna Rp60.811,20, semen warna Rp135.000, dan mortar siap pakai Rp5,98.4. Faktor utama penyebab timbulnya   sisa material yaitu kurangnya keterampilan pekerja dalam melakukan estimasi penggunaan material yang melebihi volume material yang direncanakan serta kelalaian pada saat proses pengerjaan.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID">-</dc:contributor>
	<dc:date>2025-02-04</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/12073</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v12i3.255-267</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 12, No 3 (2024); 255-267</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/12073/3854</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/3138</identifier>
				<datestamp>2022-04-11T14:01:50Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Efektivitas Proses Ozonisasi Studi Kasus : IPA dan Miniplant Dago Pakar</dc:title>
	<dc:creator>CINTHYA, CHINDY</dc:creator>
	<dc:creator>SURURI, M. RANGGA</dc:creator>
	<dc:creator>AINUN, SITI</dc:creator>
	<dc:subject xml:lang="id-ID"></dc:subject>
	<dc:description xml:lang="id-ID">AbstrakIPA dan Miniplant Dago Pakar merupakan salah satu Instalasi pengolahan air minum dengan sumber air baku berasal dari Sungai Cikapundung Hulu. Keberadaan kolam retensi yang berperan sebagai pre-treatment pada air baku Miniplant diperkirakan akan mempengaruhi karakteristik bahan organik pada air baku. Proses ozonisasi digunakan sebagai alternatif pengolahan bahan organik dengan menggunakan ozon yang berperan sebagai oksidator kuat. Tujuan dari penelitian ini adalah mengetahui efisiensi penyisihan BOD dan kekeruhan pada air baku dengan proses ozonisasi. Parameter yang diukur meliputi pH, temperatur, kekeruhan, BOD dan KSO dengan metode pengukuran mengacu kepada Â SNI dan SMWW. Penelitian dilakukan skala laboratorium menggunakan reaktor sistem batch selama 60 menit pada reaktor ozon kontaktor yang bervolume 1,5 L. Pengolahan dengan proses ozonisasi dapat mengoksidasi bahan organik menjadi senyawa yang lebih sederhana. Sampel air yang digunakan berasal dari air baku yang akan diolah di IPA dan Miniplant Dago Pakar. Efisiensi penyisihan kekeruhan pada IPA dan Miniplant secara berturut-turut adalah 77% dan 39%. Nilai BOD pada IPA lebih tinggi dibandingkan dengan Miniplant yang diduga disebabkan oleh keberadaan kolam retensi. Konsentrasi BOD pada IPA setelah dilakukan ozonisasi mengalami peningkatan sebanyak 9% sedangkan pada Miniplant peningkatan nilai BOD adalah 20%.Kata kunci: Air Baku, IPA dan Miniplant Dago Pakar, Ozonisasi, BOD, Kekeruhan</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2019-09-03</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/3138</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v7i2.90-99</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 7, No 2 (2019); 90-99</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/3138/2006</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/7178</identifier>
				<datestamp>2023-07-03T03:01:01Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">EVALUASI PARAMETER FISIK, KIMIA DAN  MIKROBIOLOGI AIR SUMUR  BOR SEBAGAI SUMBER    AIR BERSIH di KOMPLEKS PERUMAHAN    SOLARIA KOTA GORONTALO</dc:title>
	<dc:creator>Mahmud, Marike</dc:creator>
	<dc:creator>Womtami, Rahmawati</dc:creator>
	<dc:creator>Husnan, Rawiyah</dc:creator>
	<dc:creator>Saleh, Kasmat</dc:creator>
	<dc:subject xml:lang="id-ID">parameter  air ,   sumur bor</dc:subject>
	<dc:description xml:lang="id-ID">Penduduk yang padat diperkotaan menyebabkan masyarakat membeliÂ  perumahan, luas tanah yang kecil, menyebabkan masyarakat memilih sumur bor, sebagai sumber Â air bersih masyarakat.Â  Tujuan penelitian ini adalah untuk mengevaluasi parameter fisik, kimia dan mikrobiologi air sumur bor Â sebagai sumber air bersih untuk digunakan oleh masyarakat yang tinggal Â diÂ  Perumahan Solaria Kota Gorontalo dan penyebab air dapat tercemar. Pengambilan sampel dilakukan di Perumahan Solaria sebanyak 6 lokasi.Â  Sumur yang dijadikan sampel adalah sumur bor (Sumur suntik) terdiri dari Blok A,Â  B, C,Â  D,Â  E danÂ  F. Pengambilan sampel dilakukanÂ  3 kali ulangan. Parameter yang diukur adalah fisik (suhu dan TDS), kimia (besi, mangan, kesadahan ) dan parameter mikrobiologi (E.Coli dan Coliform). Analisis fisik dilakukan secara insitu. Parameter kimia di analisis di LPPT UGM dan Â mikrobiologi dilakukan pada Dinas Kesehatan Kabupaten Gorontalo. Kriteria kelayakan air menggunakan PMK 32 Tahun 2017. Hasil penelitian menunjukkan bahwaÂ  parameterÂ  Suhu dan TDS,Â Â  kesadahan dan e.coli memenuhi syarat. Parameter Mangan, Besi, Total Coliform tidak memenuhi PMK 32 Tahun 2017. Parameter Mangan dan BesiÂ  tinggi karena kondisi alamiah tanah yang dilalui air. Parameter Total Coliform di atas baku mutu karena kondisi lingkungan disekitar. </dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID">Fakultas Teknik Universitas Negeri Gorontalo</dc:contributor>
	<dc:date>2023-06-15</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/7178</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v11i1.25-36</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 11, No 1 (2023); 25-36</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/7178/3321</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/10594</identifier>
				<datestamp>2024-10-21T21:41:20Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">EVALUASI KINERJA INSTALASI PENGOLAHAN LUMPUR TINJA (IPLT) BANYUROTO KABUPATEN KULON PROGO</dc:title>
	<dc:creator>Damayanti, Ayu</dc:creator>
	<dc:creator>Anasstasia, Titi Tiara</dc:creator>
	<dc:subject xml:lang="id-ID">Evaluasi, lumpur tinja, Instalasi Pengolahan Lumpur Tinja</dc:subject>
	<dc:description xml:lang="id-ID">IPLT Banyuroto berada di Kelurahan Banyuroto, Nanggulan, Kulon Progo, Daerah Istimewa Yogyakarta yang kinerjanyaÂ belumoptimalÂ ditinjau berdasarkan aspek kuantitas dan kualitas limbah. Evaluasi ini dilakukan terhadap kinerja unit proses dalam penurunan parameter BOD, COD, dan total coliform,Â pengaruh pengolahan IPLT terhadapÂ kualitas tanah dekat outletÂ berdasarkanparameter total coliform, dan potensi padatan hasil pengolahan lumpur tinja terhadap standar mutu pupuk kompos berdasarkan parameter kadar air dan fecal coli. Metode penelitian yang digunakan berupa metode kuantitatif dan kualitatif dengan pengambilan sampel menggunakan metode purposive sampling dan grab samplingÂ serta analisis deskriptif dan matematis. Uji laboratorium menunjukkan bahwa parameter Biological Oxygen Demand (BOD), Chemical Oxygen Demand (COD) pada efluen IPLT sudah memenuhi baku mutu, sedangkan total coliform masih melebihi baku mutu menurut Permen LHK No. 68 tahun 2016. Tanah memiliki permeabilitas yang termasuk pada kelas agak lambat dengan porositas tanah berada pada kelas porous dan kandungan total coliform &gt;1.100 MPN/gr total. Pengambilan sampel tanah ini tidak berada di arah aliran yang sama, sehingga porositas dan permeabilitas tidak mempengaruhi penyebaran total coliform. Padatan hasil pengolahan dengan pengeringan 30 hari memiliki kandungan kadar air sebesar 11,392% dan Fecal coli sebesar 150 MPN/gr total serta sudah memenuhi baku mutu pupuk kompos menurut SNI 19-7030-2004.Â Â </dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2024-10-22</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/10594</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v12i2.117-132</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 12, No 2 (2024); 117-132</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/10594/3731</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/738</identifier>
				<datestamp>2022-07-20T04:51:08Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Perencanaan Sistem Instalasi Plambing Air Bersih Gedung Park View Hotel</dc:title>
	<dc:creator>Putra, Dimas Anggara</dc:creator>
	<dc:creator>Pratama, Yulianti</dc:creator>
	<dc:creator>Nurprabowo, Anindito</dc:creator>
	<dc:subject xml:lang="id-ID"></dc:subject>
	<dc:description xml:lang="id-ID">ABSTRAKPark View Hotel yang berlokasi di Bandung merupakan tempat tinggal sementara yang memerlukan air bersih untuk keperluan sanitasi bagi penghuninya. Konsep yang digunakan dalam perencanaan sistem instalasi plambing air bersih adalah mengacu pada konsep green building dengan adanya pembagian jalur pipa air bersih berdasarkan sumbernya, yaitu jalur pipa air fisrt class untuk air yang bersumber dari air tanah dan jalur pipa air second class dari air hasil pengolahan grey water. Perhitungan kebutuhan air bersih dan diameter pipa mengacu pada SNI 03-6481-2000 dan SNI 03-7065-2005. Kebutuhan air bersih adalah sebesar 73 m3/hari. Jenis pipa yang digunakan adalah pipa PPR yang biasa digunakan dalam sistem instalasi plambing air bersih pada gedung hotel. Hasil dari perhitungan diameter pipa yang dilakukan pada gedung hotel Park View yaitu menggunakan pipa dengan diameter 15 - 100 mm.Kata kunci: Park View, plambing, first class, second class, diameterÂ </dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2015-10-05</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/738</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v3i2.%p</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 3, No 2 (2015); 97-107</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/738/935</dc:relation>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/12252</identifier>
				<datestamp>2026-02-22T05:52:15Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">PENGARUH FAKTOR PERSONAL, MANAJEMEN, DAN DUKUNGAN SOSIAL TERHADAP PERILAKU KESELAMATAN  PADA PROYEK PEMBANGUNAN BSI ACEH</dc:title>
	<dc:creator>Nasliya, Raisa</dc:creator>
	<dc:creator>Suharyanto, .</dc:creator>
	<dc:subject xml:lang="id-ID"></dc:subject>
	<dc:description xml:lang="id-ID">Pekerjaan konstruksi memiliki resiko kecelakaan yang tinggi, dimana perilaku tidak aman merupakan penyebab sebagian besar dari kecelakaan tersebut. Penelitian ini bertujuan untuk mengetahui apakah terdapat pengaruh faktor personal, manajemen, dan dukungan sosial terhadap perilaku keselamatan. Pengambilan data melalui penyebaran kuesioner terhadap 122 pekerja yang terlibat dalam pembangunan Gedung BSI Aceh dengan penentuan sampel responden menggunakan teknik accidental sampling. Analisis data menggunakan Structural Equation Model – Partial Least Squared (SEM-PLS) dengan perangkat lunak SmartPLS versi 3.0. Hasil penelitian menunjukkan bahwa faktor personal memiliki pengaruh langsung terhadap perilaku keselamatan, dengan nilai t statistik 3.130 &gt; 1.96 dan P value 0.002&lt;0.05. Praktik manajemen berpengaruh terhadap perilaku keselamatan, dengan nilai t statistik 1.998 &gt; 1.96 dan P value 0.046 &lt;0,.5. Dukungan sosial berpengaruh terhadap perilaku keselamatan, dengan nilai t statistik 2.761 &gt; 1.96 dan P value 0.006 &lt;0.05. Namun, faktor personal tidak memiliki efek mediasi antara praktik manajemen dan dukungan sosial terhadap perilaku keselamatan. Diperlukan strategi yang tepat bagi manajemen agar meningkatkan perilaku keselamatan pekerja dengan meningkatkan motivasi melalui penghargaan dan pemberian hadiah, meningkatkan pengetahuan melalui pelatihan rutin dan pelatihan tambahan, serta meningkatkan praktik-praktik manajemen sehingga faktor tersebut bisa meningkatkan safety culture dan mengurangi kecelakaan kerja.Kata kunci: Faktor personal, dukungan sosial, praktik manajemen, perilaku keselamatan.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2025-10-28</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/12252</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v13i1.85-101</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 13, No 1 (2025); 85-101</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/12252/4107</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/2700</identifier>
				<datestamp>2021-03-02T16:26:15Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Valuasi Ekonomi Objek Wisata Goa  Pindul Kabupaten Gunungkidul Menggunakan Pendekatan Travel Cost Method</dc:title>
	<dc:creator>PUTRI, WIBIARIKSA</dc:creator>
	<dc:creator>JUWANA, IWAN</dc:creator>
	<dc:subject xml:lang="id-ID"></dc:subject>
	<dc:description xml:lang="id-ID">AbstrakWisata Goa Pindul Kabupaten Gunungkidul merupakan wisata penelusuran goa dengan peningkatan jumlah pengunjung yang signifikan pada setiap tahunnya. Wisata Goa Pindul merupakan barang publik sehingga dibutuhkan pendekatan untuk menerjemahkan nilai ekonomi yang dimilikinya. Salah satunya menggunakan Travel Cost Method yaitu metode valuasi ekonomi dengan memanfaatkan biaya perjalanan pengunjung sebagai nilai ekonominya.Â  Penelitian ini menggunakan dua pendekatan Travel Cost Method. Zonal Travel Cost Method (ZTCM) merupakan metode analisis biaya perjalanan yang dikeluarkan pengunjung dengan membagi jumlah pengunjung dari berbagai lokasi yang berbeda jarak. Individual Travel Cost Method (ITCM) merupakan metoda analisis biaya perjalanan menggunakan data survey yang berasal dari pengunjung secara individu dalam analisis statistik. Hasil penelitian ini diketahui nilai ekonomi total dari Goa Pindul sebesar Rp. 10.705.348.126 menggunakan ZTCM dan Rp. 26.075.382.185 menggunakan ITCM. Nilai surplus konsumen yang didapat sebesar Rp. 7.428.342.496 menggunakan ZTCM dan Rp. 10.399.524.104 menggunakan ITCM. Nilai ekonomi yang diketahui nantinya dapat dimanfaatkan sebagai alternatif pengelolaan lingkungan.Kata kunci: Goa Pindul, Nilai Ekonomi Total, Travel Cost Method, Surplus Konsumen.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2019-02-22</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/2700</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v7i1.1-11</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 7, No 1 (2019); 1-11</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/2700/1993</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/5961</identifier>
				<datestamp>2022-12-17T17:36:16Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">TINJAUAN SINGKAT BIO-ELEKTROKINETIK REMEDIASI PADA TANAH TERCEMAR HIDROKARBON MINYAK BUMI</dc:title>
	<dc:creator>Madonna, Sandra</dc:creator>
	<dc:subject xml:lang="id-ID">Bioremediasi;Bio-elektrokinetik;Elektrokinetik Remediasi;Tanah terkontaminasi Minyak Bumi</dc:subject>
	<dc:description xml:lang="id-ID">Bioremediasi telah banyak diaplikasikan untuk pemulihan tanah yang tercemar hidrokarbon minyak bumi, namun dalam aplikasinya yang luas masih dibatasi oleh karakterisik polutan, karakteristik tanah dan karakteristik mikroba pendegradasi dalam beradaptasi pada lingkungan yang berbeda. Tantangan dalam bioremediasi tanah tercemar hidrokarbon minyak bumi selain kompleksitas senyawa polutan dan juga bersifatÂ rekalsitran, sertatoksik sehingga polutan sulit terbiodegradasi dan menyebabkan laju degradasinya berjalan lambat. Lambatnya laju degradasi limbah organik dipengaruhi oleh enzim-enzim degradatif mikroba yang sulit mengkatalis reaksi degradasi limbah dari senyawa xenobiotik atau yang senyawa yang tidak alami, karakteristik senyawa pencemar yang sukar larut dalam air, dan mengandung senyawa toksik bagi mikroorganisma pendegradasi. Bioremediasi tanah tercemar hidrokarbon minyak bumi umumnya akan berlangsung dalam hitungan bulan, waktu degradasi tersebut dapat dipercepat dengan menggabungkannya dengan teknikÂ elektrokinetikremediasi dan meningkatkan bioavailibiltas denganmelakukan biostimulasi pada tanah tercemar tersebut, sehingga remediasi dapat berlangsung dalam hitungan hari bahkan hitungan jam.Â Makalah ini memberikan ulasan tentangÂ pegabunganÂ teknologi remediasi untuk tanah yang terkontaminasi minyak bumi. Metode yang dibahas meliputiÂ Bioremediasi danÂ Elektrokinetik remediasi yang dikaitkan denganefektifitas degradasi, waktu degradasi,kelebihan, kekurangan, dan prospek pengembangannya di masa depan. Penekanan pada makalah ini adalah tidak ada teknologi remediasi tunggal yang dianggap sebagai solusi terbaik untuk remediasi tanah yang terkontaminasi minyak bumi yang bersifat komplek</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2022-11-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/5961</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v10i3.175-187</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 10, No 3 (2022); 175-187</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/5961/3086</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/9159</identifier>
				<datestamp>2024-07-16T07:42:26Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">POTENSI BAKTERI SEDIMEN MANGROVE DALAM MENDEGRADASI PLASTIK MENGGUNAKAN METODE KOLOM WINOGRADSKY</dc:title>
	<dc:creator>Ni'am, Achmad Chusnun</dc:creator>
	<dc:creator>Ainiyah, Siti Irhayatul</dc:creator>
	<dc:creator>Ratnawati, Rhenny</dc:creator>
	<dc:subject xml:lang="id-ID"></dc:subject>
	<dc:description xml:lang="id-ID">Plastik merupakan suatu material industri dengan banyak kelebihan ekonomis sehingga diproduksi dan digunakan meluas hampir di seluruh aspek kehidupan manusia. Namun, plastik memiliki kekurangan yaitu sulit terurai di lingkungan karena ikatan rantai karbon yang panjang. Akibatnya, diperlukan lebih dari satu dekade agar plastik terdegradasi dan termineralisasi ke lingkungan. Peningkatan jumlah konsumsi plastik tentu menambah dampak akibat sampah plastik yang dibuang ke lingkungan. Biodegradasi adalah salah satu upaya untuk mengelola sampah plastik. Tujuan penelitian ini yaitu untuk menganalisis potensi bakteri yang diisolasi dari sedimen Mangrove Wonorejo Surabaya dalam mendegradasi plastik Polyethylene, Polypropylene, dan Polystyrene menggunakan metode Kolom Winogradsky. Substrat yang digunakan adalah pasir dan tanah, dengan Bushnell-Haas broth sebagai media tumbuh bakteri, dan plastik uji ukuran 10x3 cm. Besar persen degradasi dihitung berdasarkan selisih berat kering sebelum dan sesudah masa inkubasi selama 12 minggu. Sebanyak 17 isolat bakteri berhasil diisolasi dari masing-masing sumber sampel. Persen degradasi terbesar ditemukan pada sampel sedimen mangrove titik 3 substrat pasir sebesar 82.3% pada plastik PP. Sedangkan plastik PS diperoleh persen degradasi sebesar 34.1% pada sedimen mangrove titik 5 substrat tanah.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2024-07-16</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/9159</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v12i1.1-10</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 12, No 1 (2024); 1-10</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/9159/3672</dc:relation>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/downloadSuppFile/9159/779</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/513</identifier>
				<datestamp>2021-03-12T22:35:39Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Perhitungan Kuantitatif Skor Risiko Kecelakaan menggunakan Metode Fine dan Matriks Robinson  (Studi Kasus PT.X)</dc:title>
	<dc:creator>Yolanda, Fransis</dc:creator>
	<dc:creator>Soemirat, Juli</dc:creator>
	<dc:creator>Pharmawati, Kancitra</dc:creator>
	<dc:subject xml:lang="id-ID"></dc:subject>
	<dc:description xml:lang="id-ID">ABSTRAKRisiko kecelakaan kerja di sektor konstruksi cukup tinggi dari sektor lain, sehingga diperlukan penelitian untuk perhitungan SR (Skor Risiko) kuantitatif. Perhitungan SR kuantitatif menggunakan Metode Fine dan Matriks Robinson, Matriks Robinson memberikan nilai E (Paparan), C (Konsekuensi), dan P (Kemungkinan) untukÂ  perhitungan SR menggunakan Metode Fine. SR tertinggi hasil perhitungan kuantitatif adalah bagijejas dalam, luka sayat, dan luka tusuk pada bagian jari tangan sebesar 196,842 berjumlah 17 kasus, kaki &amp; lutut sebesar 130,263 berjumlah 15 kasus, dan pergelangan dan tangan sebesar 81,053 berjumlah 7 kasus. Dapat diketahui perhitungan SR kuantitatif selain memperhitungkan keparahan, juga memperhitungkan frekuensi. SR kuantitatif menunjukan prioritas untuk pencegahan kecelakaan agar kecelakaan yang sama tidak terulang kembali dan angka kecelakaan dapat turun dengan cepat. Dengan demikian metode kuantitatif juga memberi peluang untuk perbaikan secara berkelanjutan sampai tercapainya kondisi zero accident.Kata kunci : Industri Konstruksi, Skor Risiko kuantitatif, Metode Fine, Matriks Robinson.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2015-04-06</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/513</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v2i2.%p</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 2, No 2 (2014); 58-69</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/513/719</dc:relation>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/1882</identifier>
				<datestamp>2021-03-02T15:18:34Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Hubungan Partisipasi Masyarakat terhadap Sistem Pengelolaan Sampah di Kelurahan Sukaluyu</dc:title>
	<dc:creator>PRATIWI, FINKA AYU</dc:creator>
	<dc:creator>SOEMIRAT, JULI</dc:creator>
	<dc:creator>AINUN, SITI</dc:creator>
	<dc:subject xml:lang="id-ID"></dc:subject>
	<dc:description xml:lang="id-ID">AbstrakMeningkatnya timbulan sampah salah satunya dipengaruhi oleh semakin bertambahnya jumlah penduduk. Peningkatan timbulan sampah di Kota Bandung pada tahun 2014 yaitu sebesar 1.523 ton/hari sedangkan tahun 2015 sebesar 1.670 ton/hari. Meskipun demikian, tingkat pelayanan sampah di Kota Bandung pada tahun 2015 sebesar 51,85%. Artinya, sekitar 48,15% tidak terkelola, sehingga perlu adanya partisipasi dari masyarakat. Oleh karena itu, dalam upaya mengatasimasalah sampah, perlu dilakukan peningkatan peran serta masyarakat sejak dari sumber. Tujuan dari penelitian ini adalah mengetahui hubungan partisipasi masyarakat terhadap sistem pengelolaan sampah di Kelurahan Sukaluyu. Pengukuran tingkat partisipasi masyarakat dengan menggunakan konsep 8 (delapan) tangga dari Arnstein. Data penelitian diperoleh melalui wawancara yang dianalisis dengan menggunakan regresi linear sederhana. Hasil pengukuran partisipasi masyarakat menunjukkan bahwa tingkat partisipasi masyarakat terbesar terdapat pada tingkat manipulasi sebesar 63% dan sebesar 77,9% adanya pengaruh dari sistem terhadap partisipasi masyarakat. Disarankan dengan adanya pendidikan lingkunganmaka akan meningkatkan partisipasi masyarakat terhadap pengelolaan sampah.Kata Kunci : Arnstein, Pengelolaan Sampah, Tingkat Partisipasi Masyarakat, Kelurahan Sukaluyu,</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2018-04-17</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/1882</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v6i1.%p</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 6, No 1 (2018)</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/1882/1752</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/5720</identifier>
				<datestamp>2022-11-28T21:19:48Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">PEMANFAATAN KITOSAN DAN KARBON AKTIF DARI AMPAS TEH DALAM MENURUNKAN LOGAM KADMIUM DAN ARSEN PADA LIMBAH INDUSTRI PT X</dc:title>
	<dc:creator>Nurhidayanti, Nisa</dc:creator>
	<dc:creator>Suwazan, Dhonny</dc:creator>
	<dc:creator>Fahmi, Angga Bahrul</dc:creator>
	<dc:creator>Riyadi, Agus</dc:creator>
	<dc:subject xml:lang="id-ID">biosorben, kitosan, ampas teh, kadmium, arsen</dc:subject>
	<dc:description xml:lang="id-ID">Industri tekstil sebagai salah satu komoditas unggulan industri di Indonesia, yang dalam proses produksinya menggunakan bahan pewarna berupa dyes berpotensi menyebarkan logam berat yang terkandung dalam limbahnya apabila limbah cair hasil produksi industri tekstil tidak diolah dengan baik. Salah satu metode penghilangan logam berat pada limbah yaitu menggunakan metode adsorpsi menggunakan biosorben. Pada penelitian ini telah berhasil disintesis adsorben hasil kombinasi kitosan dan karbon aktif dari ampas teh. Hasil karakterisasi diperoleh kadar karbon terikat sebesar 78,09%. Tahap awal dilakukan pengujian kandungan logam berat pada PT X dan diperoleh kandungan awal logam kadmium (Cd) sebesar 1,15 mg/L dan logam arsen (As) sebesar 5,74 mg/L. Biosorben kombinasi kitosan dan karbon aktif dari ampas teh diaplikasikan sebagai adsorben dalam penghilangan logam berat kadmium (Cd) dan arsen (As) pada limbah industri tekstil PT X dengan variasi massa adsorben. Hasil penelitian menunjukkan bahwa dengan penambahan karbon aktif sebesar 1,4 gr menghasilkan persen efektivitas tertinggi dalam penghilangan logam berat kadmium (Cd) sebesar 92,50% dan arsen (As) sebesar 85,32%.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID">DIPA Direktorat Jenderal Pendidikan Tinggi, Kementerian Pendidikan, Kebudayaan, Riset, dan Teknologi</dc:contributor>
	<dc:date>2022-06-08</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/5720</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v10i2.91-102</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 10, No 2 (2022); 91-102</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/5720/2933</dc:relation>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/downloadSuppFile/5720/370</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/8055</identifier>
				<datestamp>2023-10-31T02:53:17Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">EVALUASI SISTEM JARINGAN DISTRIBUSI AIR MINUM PDAM KOTA MOJOKERTO INSTALASI PENGOLAHAN AIR (IPA) WATES  ZONA PELAYANAN PENGOLAHAN AIR PRAJURIT KULON</dc:title>
	<dc:creator>Barikiyah, Saeril</dc:creator>
	<dc:creator>Utama, Teguh Taruna</dc:creator>
	<dc:creator>Nengse, Sulistya</dc:creator>
	<dc:creator>Setyowati, Rr Diah Nugraheni</dc:creator>
	<dc:subject xml:lang="id-ID">Distribusi; Tekanan; Software Epanet 2.0</dc:subject>
	<dc:description xml:lang="id-ID">AbstrakTingkat kehilangan air PDAM Maja TirtaÂ  sebesar 46,51% yang terdiri dari kehilangan air komersial sebesar 8,52% dan kehilangan air sebesar 37,99%Â  melebihi kriteria batas maksimum menurut Menteri Pekerjaan Umum dan Perumahan Rakinstalayat Republik Indonesia No 27/PRT/M/2016 pada batas maksimum yaitu sebesar 20%. Tujuan penelitian ini untuk mengevaluasi dan mengoptimalisasikan jaringan distribusi air pada zona pelayanan Prajurit Kulon. Metode evaluasi pada jaringan distribusi IPA Wates dengan simulasi software Epanet 2.0 dengan kecepatan air dalam pipa dan tekanan air dalam pipa dibandingan dengan Peraturan Menteri Pekerjaan Umum dan Perumahan Rakyat Republik Indonesia No 27/PRT/M/2016. Tekanan air dalam pipapada zona pelayanan Prajurit Kulon yang mengalami negtif pressure yaitu sebesar -3.29 m, kecepatan air dalam pipa yaiitu sebesar 22.72 m/s. Optimalisasi sistem jaringan distribusi IPA Wates zona pelayanan Prajurit Kulon yaitu denganmengganti diameter pipa adalah solusi untuk menghilangkan negatif tekanan, sehingga air dari reservoir dapat dialirkan ke ujung pipa.Kata kunci: Distribusi, Tekanan, Software Epanet 2.0AbstractThe water loss rate for PDAM Maja Tirta is 46.51%, consisting of 8.52% commercial water loss and 37.99% water loss exceeding the maximum limit criteria according to the Minister of Public Works and Public Housing of the Republic of Indonesia No. 27/PRT/M/ 2016 at the maximum limit of 20%. The purpose of this research is to evaluate and optimize the water distribution network in Prajurit Kulon service zone. The evaluation method for the Wates IPA distribution network is using Epanet 2.0 software simulation with water velocity in the pipes and water pressure in the pipes compared to the Regulation of the Minister of Public Works and Public Housing of the Republic of Indonesia No 27/PRT/M/2016. The water pressure in the pipe at the Kulon Soldier service zone which experiences negative pressure is -3.29 m, the water velocity in the pipe is 22.72 m/s. Optimization of the Wates IPA distribution network system in the Warrior Kulon service zone, namely by changing the pipe diameter is a solution to eliminate negative pressure, so that water from the reservoir can flow to the end of the pipe.Keywords: Distribution, Pressure, Software Epanet 2.0.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2023-10-31</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/8055</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v11i2.152-161</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 11, No 2 (2023); 152-161</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/8055/3443</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/12432</identifier>
				<datestamp>2025-07-02T08:03:41Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">MODIFIKASI TRIPIKON-S DENGAN BIOBALL DAN FILTER IJUK UNTUK PENGOLAHAN LIMBAH ARTIFISIAL BLACK WATER DAN DOMESTIK TERCAMPUR</dc:title>
	<dc:creator>Karmilia, Alya</dc:creator>
	<dc:creator>Halomoan, Nico</dc:creator>
	<dc:creator>Soewondo, Prayatni</dc:creator>
	<dc:subject xml:lang="id-ID">Tripikon-S, bioball, filter ijuk, pengolahan air limbah, black water</dc:subject>
	<dc:description xml:lang="id-ID">Tripikon-S merupakan septic tank vertikal yang terdiri dari tiga pipa konsentris septik untuk daerah spesifik. Tripikon-S memiliki efisiensi penyisihan BOD 75% dan penyisihan nutrient yang tergolong rendah sehingga diperlukan modifikasi untuk mencapai efisiensi yang lebih baik. Dilakukan modifikasi tripikon-S dengan menambahkan bioball pada pipa terluar dan filter ijuk pada outlet Tripikon-S untuk menguji kinetika pada reaktor dan kinerja reaktor dalam pengolahan limbah black water dan domestik tercampur. Seeding dan aklimatisasi dilakukan dalam kondisi batch dengan variasi beban COD 500, 750 dan 1.000 mg/L, dilanjutkan pengujian kinerja reaktor dalam kondisi kontinyu. Diperoleh µmax 0,0524/jam, Ks 942,277 mg/L COD/jam, dan yield 2,571. Laju degradasi substrat (k) pada konsentrasi 500, 750 dan 1.000 mg/L diperoleh berturut-turut 0,053/jam, 0,0537/jam dan 0,0442/jam. Efisiensi penyisihan black water menunjukkan hasil yang lebih baik pada reaktor modifikasi COD 67,76% dan TSS 87,51%, hasil uji t (p = 0,818) mengindikasikan tidak terdapat perbedaan kinerja yang signifikan pada reaktor modifikasi dan kontrol terhadap pengolahan limbah black water. Penggunaan filter ijuk pada reaktor tripikon-S memberikan peningkatan efisiensi pada parameter COD 28,41% dan TSS  8,89%. Hasil uji (p = 0,036) menunjukkan tripikon-S modifikasi lebih baik digunakan dalam pengolahan limbah black water daripada limbah domestik tercampur.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID">Resilient Indonesia and Slum Envisioned (RISE)</dc:contributor>
	<dc:date>2025-02-04</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/12432</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v12i3.327-339</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 12, No 3 (2024); 327-339</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/12432/3859</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/1047</identifier>
				<datestamp>2023-03-01T06:37:02Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Perencanaan Sistem Instalasi Plambing Air Bersih Gedung Hotel Tebu</dc:title>
	<dc:creator>AFFIANDI, JUNIA</dc:creator>
	<dc:creator>PHARMAWATI, KANCITRA</dc:creator>
	<dc:creator>NURPRABOWO, ANINDITO</dc:creator>
	<dc:subject xml:lang="id-ID"></dc:subject>
	<dc:description xml:lang="id-ID">ABSTRAKKota Bandung merupakan kota pariwisata yang banyak dikunjungi oleh para wisatawan, maka diperlukan tempat penginapan sementara berupa hotel. Hotel Tebu merupakan hotel berbintang. Untuk memenuhi kebutuhan air bersih sehari-hari pada penghuni hotel maka dirancang sistem perpipaan air bersih, perencanaan sistem instalasi plambing air bersih di hotel Tebu mengacu pada standar SNI 03-6481-2002 dan SNI 03-7065-2005. Konsep Green Building pada aspek konservasi air diterapkan pada perencanaan plambing air bersih karena persediaan sumbar air tanah yang semakin berkurang di Kota Bandung, didalam konsep Green Building sistem instalasi plambing air bersih akan dipisahkan menjadi dua jalur berdasarkan kegunaannya, yaitu air bersih kelas satu dan kelas dua. Penggunaan konsep Green Building ini menghasilkan penghematan air sebesar 54,43 % dari total kebutuhan air bersih sebesar 79 m3/hari. Hasil perhitungan dan penentuan jalur ini menghasilkan jalur pipa air bersih dengan diameter pipa mendatar 20 sampai 80 mm, dan diameter pipa tegak 50 sampai 80 mm.Kata kunci: plambing, green building, konservasi air</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2016-09-08</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/1047</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v4i2.%p</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 4, No 2 (2016); 97-105</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/1047/1271</dc:relation>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/3776</identifier>
				<datestamp>2022-11-14T05:46:10Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Proses Seeding dan Aklimatisasi pada Anaerobic Trickling Reactor</dc:title>
	<dc:creator>ADI SEMARTA, I WAYAN WINDU</dc:creator>
	<dc:creator>HARTATI, ETIH</dc:creator>
	<dc:creator>SALAFUDIN, SALAFUDIN</dc:creator>
	<dc:subject xml:lang="id-ID"></dc:subject>
	<dc:description xml:lang="id-ID">AbstrakÂ Pertumbuhan biomassa terlekat ditentukan oleh proses seeding dan aklimatisasi. Tujuan penelitian ini yaitu mengetahui proses seeding dan aklimatisasi pada anaerobic trickling reactor. Metoda penelitian yang digunakan meliputi persiapan reaktor hidrolisis dan 3 buah anaerobic trickling reactor dengan media yang berbeda, serta persiapan bahan meliputi inokulum dan substrat. Parameter yang diukur yaitu densitas, kadar air dan volatil, C-Organik, NTK, pH, temperatur, TAV, COD, dan alkalinitas mengacu pada SNI dan standard methods. Hasil penelitian ini yaitu saat proses seeding, nilai pH 6,87 hingga pH 7,52, temperatur 27oC hingga 28oC, dan ketiga media mengalami pertambahan berat rata-rata sebesar 0,5421 gram/media (bioball rambutan) (12,93 %), 0,7158 gram/media (bioball bola) (11,47 %), dan 0,0449 gram/media (media straws) (13,95 %). Steady state aklimatisasi terjadi pada hari ke-14 hingga hari ke-20 yang ditandai dengan penurunan konsentrasi COD yang konstan. Selama seeding dan aklimatisasi terbentuk biogas. Kesimpulan penelitian ini yaitu proses seeding dan aklimatisasi ditandai dengan terbentuknya lapisan biofilm dan adanya penurunan konsentrasi COD substrat.Kata kunci: Anaerob, Seeding dan Aklimatisasi, Anaerobic Trickling ReactorAbstractAttached biomass growth is determined by seeding and acclimatization process. The purpose of this research is to know the seeding and acclimation process in anaerobic trickling reactor. The research method used includes the preparation of the tool that is hydrolysis reactor and 3 pieces of anaerobic trickling reactor with different media, as well as the preparation of materials including inoculum and substrate. Parameters measured were density, water content and volatile, C-Organic, NTK, pH, temperature, TAV, COD, and alkalinity refer to SNI and standard methods. The result of this research is when seeding process, pH value 6,87 to pH 7,52, temperature 27oC until 28oC, and third media have average weight gain of 0,5421 gram/medium (rambutan bioball) (12,93 %), 0,7158 grams/medium (spherical bioball) (11,47 %), and 0,0449 gram/medium (media straws) (13,95 %). Steady state acclimatization occurs on the 14th day until the 20th day marked by a constant decrease in COD concentrations. During seeding and acclimatization formed biogas.The conclusion of this research is the seeding and acclimatization process is characterized by the formation of biofilm layer and the decrease of COD concentration.Keywords: Anaerobes, Seeding and Acclimatization, Anaerobic Trickling Reactor</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2020-03-03</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/3776</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v8i1.38-49</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 8, No 1 (2020); 36-47</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/3776/2296</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/7994</identifier>
				<datestamp>2023-07-03T03:07:45Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">PERENCANAAN INSTALASI PENGOLAHAN LUMPUR IPA PARIT MAYOR PERUMDA AIR MINUM TIRTA KHATULISTIWA KOTA PONTIANAK</dc:title>
	<dc:creator>Mulyanto, Rahmat</dc:creator>
	<dc:creator>Winardi, Winardi</dc:creator>
	<dc:creator>Apriani, Isna</dc:creator>
	<dc:subject xml:lang="id-ID">Lumpur; pengolahan; SNI; sludge drying bed</dc:subject>
	<dc:description xml:lang="id-ID">Peraturan Pemerintah Nomor 112 Tahun 2015 tentang Sistem Penyediaan Air Minum (SPAM), menyatakan bahwa sistem penyediaan air minum bertujuan untuk menyediakan pelayanan air minum untuk memenuhi hak rakyat atas air minum dapat diselenggarakan oleh BUMN, BUMD, maupun badan usaha lainya. Perumda Air Minum Tirta Khatulistiwa merupakan Penyedia air minum yang berada di Kota Pontianak yang memiliki Instalasi Pengolahan Air (IPA) Parit Mayor yang melayani masyarakat Pontianak Timur dengan air baku sungai kapuas. Jenis residu yang akan dihasilkan dari IPA dengan menggunakan air sungai akan menghasilkan lumpur sebagai sisa dari pengolahan. Residu lumpur akan berdampak ke lingkungan apabila di buang secara langsung sehingga diperlukan rancangan untuk mendesain unit pengolahan lumpur. Perancangan pengolahan dapat menggunakan SNI 7510 tahun 2011, menggunakan data pada tahun 2020. Dirancang bangunan berjumlah empat bak yang terdiri dari bak penampung,bak sludge drying bed, bak supernatan, dan bakÂ  dry cake. luas area perencanaan yang dibutuhkan sebesar 345,902 m2 , sehingga luas lahan yang tersedia masih mencukupi untuk dibangunnya pengolahan lumpur. Oleh karena itu, dilakukan perencanaan pengolahan lumpur untuk mengolah lumpur residu.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2023-06-15</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/7994</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v11i1.83-94</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 11, No 1 (2023); 83-94</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/7994/3327</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header status="deleted">
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/4670</identifier>
				<datestamp>2022-11-14T05:46:10Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/12003</identifier>
				<datestamp>2024-10-21T21:41:20Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">ESTIMATION OF EMISSION TAX VALUE OF HOSPITALITY AND RESTAURANT INDUSTRY IN BOGOR CITY, WEST JAVA, INDONESIA</dc:title>
	<dc:creator>Go, Riska Tezara</dc:creator>
	<dc:creator>Aini, Nur</dc:creator>
	<dc:creator>Renjaan, Irene Paula</dc:creator>
	<dc:subject xml:lang="id-ID">emission tax fees; hotel and restaurant emissions; increase in the number of hotels and restaurants; green open space area;</dc:subject>
	<dc:description xml:lang="id-ID">The number of hotels and restaurants in Bogor City has increased annually. According to the Bogor City Tourism and Culture Office (2018), the number of hotels rose from 53 units in 2016 to 87 units, while restaurants increased from 162 units to 680 units. This growth leads to higher CO2 emissions, while green open spaces remain static. This study aims to estimate CO2 emissions from the hotel and restaurant industry using the TIER-1 method, determine the urban park land needed to absorb these emissions using a quantitative descriptive approach, estimate the CO2 emission tax value based on the cost of creating urban parks, and propose alternative policy implications for emission tax implementation using a qualitative descriptive approach. The results indicate that hotels in Bogor City produce 3221 tons of CO2 per year, and restaurants produce 9583 tons per year. The current green open spaces are insufficient to absorb these emissions, necessitating additional urban park land. Specifically, the hotel industry requires 57 hectares of city park, and the restaurant industry requires 167 hectares. Funding for the development of these parks is to be sourced from emission taxes levied on hotels and restaurants. The proposed emission tax is Rp 3415 per room per night for hotels and Rp 239 per transaction for restaurants.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2024-10-22</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/12003</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v12i2.172-186</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 12, No 2 (2024); 172-186</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/12003/3737</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/14321</identifier>
				<datestamp>2026-04-03T02:44:45Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">PERANCANGAN PEMANENAN AIR HUJAN PADA PESANTREN DARUL AITAMI KABUPATEN ACEH BARAT</dc:title>
	<dc:creator>Effendi, Rijal</dc:creator>
	<dc:creator>Rohendi, Aulia</dc:creator>
	<dc:creator>Ikhwali, M.Faisi</dc:creator>
	<dc:subject xml:lang="id-ID">pemanenan air hujan; air bersih; asrama; analisis curah hujan.</dc:subject>
	<dc:description xml:lang="id-ID">Air bersih Pesantren Darul Aitami sebagian besar bersumber dari air tanah, namun jumlah dan kualitasnya belum memadai. Penelitian ini memiliki tujuan guna mengevaluasi potensi air hujan dan merancang sistem pemanenan air hujan (PAH) sebagai opsi tambahan sumber air bersih. Kualitas air hujan dianalisis dengan pengambilan sampel selama lima hari hujan berturut-turut, sedangkan analisis curah hujan menggunakan distribusi Log Normal dan metode Mononobe dengan periode ulang 2 tahun (54,46 mm/jam). Hasil menunjukkan bahwa air hujan memenuhi standar kualitas air bersih dan cukup untuk memenuhi kebutuhan harian empat asrama, atau satu asrama dan mushola. Sistem PAH dirancang dengan pipa vertikal dan talang berdiameter 4–10 inci, pipa horizontal 3 inci, serta tangki penampungan masing-masing 2.000–5.700 liter. Penelitian ini menunjukkan bahwa pemanenan air hujan merupakan solusi alternatif yang layak dan berkelanjutan untuk penyediaan air bersih di fasilitas pendidikan.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2026-03-05</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/14321</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v13i2.147-161</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 13, No 2 (2025); 147-161</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/14321/4320</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/3134</identifier>
				<datestamp>2021-03-02T16:44:24Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Pengaruh Waktu Detensi pada Anaerobik Digester Sistem dua Tahap dengan Substrat Tanah Gambut terhadap Produktivitas Biogas</dc:title>
	<dc:creator>Putra, Alca Pratama</dc:creator>
	<dc:creator>HARTATI, ETIH</dc:creator>
	<dc:creator>SALAFUDIN, SALAFUDIN</dc:creator>
	<dc:subject xml:lang="id-ID"></dc:subject>
	<dc:description xml:lang="id-ID">AbstrakIndonesia memiliki 50% dariÂ  luas lahan gambut yang ada di dunia. Tanah gambut merupakan tanah yang berasal dari proses dekomposisi materi organik dari sisa tumbuhan. Materi organik yang terkandung dalam tanah gambut dapat dimanfaatkan sebagai substrat dalam pembentukan biogas. Keberadaan tanah gambut di Indonesia berkisar 21 juta hektar sehingga berpotensi besar dalam membuat biogas dari tanah gambut. Biogas dapat dimanfaatkan sebagai bahan bakar alternatif yang ramah lingkungan. Tujuan dari penelitian ini adalah mengetahui potensi tanah gambut sebagai substrat dalam pembentukan biogas. Metode yang digunakan dalam penelitian ini adalahÂ  two stage digestion system dimana tahap pembentukan asam dilakukan di reaktor hidrolisis secara batch sedangkan tahap pembentukan gas CH4 dilakukan di reaktor metanogenesis secara kontinu. Variasi yang digunakan pada penelitian ini adalah waktu detensi 1 hari dan 4 hari. Hasil optimum yang didapatkan pada variasi waktu detensi 4 hari dengan laju produksi biogasÂ  sebesar 395 ml/hari dan konsentrasi gas CH4 sebesar 61%.Â Kata Kunci : Tanah gambut, Biogas, Waktu detensi, two stage digestion system</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2019-09-03</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/3134</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v7i2.56-67</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 7, No 2 (2019); 56-67</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/3134/2005</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/7246</identifier>
				<datestamp>2022-12-17T17:36:16Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">PERENCANAAN SISTEM PENGELOLAAN SAMPAH DI PASAR KERAMAT INDAH KUALA DUA KABUPATEN KUBU RAYA</dc:title>
	<dc:creator>Dikta, Berta</dc:creator>
	<dc:creator>Arifin, Arifin</dc:creator>
	<dc:creator>Winardi, Winardi</dc:creator>
	<dc:subject xml:lang="id-ID">Pasar, Pengelolaan Sampah, Timbulan Sampah, Perencanaan</dc:subject>
	<dc:description xml:lang="id-ID">Keadaan Pasar Keramat Indah dilihat pada kondisi kebersihan pasar masih kurang terjaga, banyaknya sampah berserakan di sekitar pasar serta tingginya jumlah volume sampah menyebabkan sampah berserakan diluar TPS sehingga diperlukan perencanaan sistem pengelolaan sampah yang benar. Perencanaan ini bertujuan untuk menghitung timbulan berat dan volume sampah serta komposisi sampah serta merencanakan sistem pengelolaan sampah. Perhitungan sampel sampah menggunakan teknik Purposive Sampling. Pengambilan dan pengukuran sampel sampah berdasarkan SNI 19-3694-1994 dilakukan selama 8 hari. Timbulan sampah organik sebesar 0,0022 m3/unit/hari dan sampah anorganik 0,0013 m3/unit/hari. Persentase komposisi sampah organik 62% danÂ  sampah anorganik 38%. Sistem pengelolaan sampah yang direncanakan berdasarkan aspek teknik operasional yaitu pemilahan sampah dilakukan mulai dari sumber dan dipilah antara sampah organik dan anorganik. Wadah individual digunakan untuk sampah organik dan sampah anorganik dan diletakkan pada masing-masing pedagang. Pengumpulan dilakukan pada siang hari jam 12.00 â€“ 14.00 WIB dan dipindahkan oleh petugas kebersihan pasar pada kontainer terpilahÂ  yang terletak di area depan pasar dengan volume sebesar 6 m3. Sampah yang telah terpilah diangkut dan dikelola menjadi pupuk kompos dan didaur ulang oleh pihak Bank Sampah Limbung Mandiri Kubu Raya. Perencanaan sistem pengelolaan sampah ini diharapkan dapat menyelesaikan permasalahan sampah di Pasar Keramat Indah.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2022-11-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/7246</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v10i3.242-251</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 10, No 3 (2022); 242-251</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/7246/3092</dc:relation>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/downloadSuppFile/7246/527</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/10738</identifier>
				<datestamp>2024-10-17T00:28:32Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">PENYISIHAN KEKERUHAN DAN NATURAL ORGANIC MATTER (NOM) PADA UNIT KOAGULASI-FLOKULASI INSTALASI PENGOLAHAN AIR MINUM DI ASIA TENGGARA : STUDI LITERATUR</dc:title>
	<dc:creator>Sururi, Mohamad Rangga</dc:creator>
	<dc:creator>Hardika, Hardika</dc:creator>
	<dc:subject xml:lang="id-ID">Kekeruhan, koagulasi, dosis koagulan, triptofan</dc:subject>
	<dc:description xml:lang="id-ID">Kekeruhan dan senyawa organik (NOM) merupakan parameter penting yang harus diperhatikan pada operasi proses pengolahan air minum. Unit koagulasi-flokulasi memainkan peran krusial dalam menghilangkan kekeruhan dan NOM dari air baku. Oleh karena itu, tinjauan ini bertujuan untuk menyelidiki berbagai teknik dan strategi yang telah dikembangkan dan diuji untuk meningkatkan efisiensi penyisihan kekeruhan dan DOM pada unit koagulasi-flokulasi. Review ini melakukan tinjauan sistematis terhadap literatur yang relevan yang dipublikasikan 10 tahun terakhir untuk mengidentifikasi teknik dan strategi yang telah diusulkan dan diuji dalam upaya meningkatkan penyisihan kekeruhan dan DOM pada unit koagulasi-flokulasi pada instalasi pengolahan air minum. Berbagai parameter yang mempengaruhi efisiensi unit koagulasi-flokulasi, diantaranya jenis koagulan, dosis koagulan, parameter kimia air, serta pengaruh keberadaan NOM dieksplorasi secara mendalam. Hasil review menunjukan bahwa parameter kimia air memiliki peran penting dalam mencapai efisiensi penyisihan kekeruhan yang tinggi pada kondisi air sungai tercemar. Beberapa studi menunjukkan penggunaan koagulan tawas menghasilkan efisiensi penyisihan sebesar 85,27% dengan kondisi pengolahan pH asam, temperatur optimal, dan tingkat kekeruhan sedang. Dalam hal ini, dosis koagulan minimal sebesar 20 mg/L dapat digunakan. Namun, pada beberapa studi lainnya hanya menghasilkan efisiensi penyisihan kekeruhan â‰¤70%. Selain parameter kimia air, keberadaan senyawa NOM, terutama triptofan yang berasal dari aktivitas non-alami dalam air baku juga dapat menurunkan efisiensi. Sehingga, mengakibatkan peningkatan dosis koagulan dan meningkatkan risiko kegagalan proses koagulasi-flokulasi. Meskipun telah ada kemajuan dalam teknik pengolahan air minum, parameter NOM masih jarang dipertimbangkan di IPAM Indonesia. Oleh karena itu, diperlukan penelitian lebih lanjut untuk memahami pengaruh keberadaan NOM pada air baku sungai di Indonesia.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2024-07-16</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/10738</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v12i1.63-79</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 12, No 1 (2024); 63-79</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/10738/3677</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/734</identifier>
				<datestamp>2022-01-20T21:24:15Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Kelarutan Ozon pada Proses Ozonisasi Konvensional dan Advanced Oxidation Process (O3/H2O2) pada Lindi Effluent Pengolahan</dc:title>
	<dc:creator>Gelardiansyah, Sandi</dc:creator>
	<dc:creator>Sururi, Mohamad Rangga</dc:creator>
	<dc:creator>Ainun, Siti</dc:creator>
	<dc:subject xml:lang="id-ID"></dc:subject>
	<dc:description xml:lang="id-ID">AbstrakLindi merupakan limbah cair yang dihasilkan dari proses pengurugan. Proses dengan ozon maupun AOP (O3/H2O2) dapat diterapkan sebagai pengolahan lanjutan mengingat efisiensi IPAL (Instalasi Pengolahan Air Lindi) eksisting hanya menyisihkan COD sebesar 13,94%. Transfer gas dipengaruhi oleh variasi perlakuan, dalam hal ini pengukuran KLaO3bertujuan untuk mengetahui kelarutan ozon yang ada di setiap variasi. Variasi perlakuan diantaranyadengan ozonisasi konvensional dan AOP (ozon/H2O2 dengan dosis 1,197 g/L dan 1,795 g/L). Ozon dihasilkan dari generator yang dialiri oksigen murni dengan debit 3 L/menit dan dikontakkan dengan lindi pada kondisi suhu ruang (25Â±3ÂºC) dengan sistem semi batch. Proses dengan AOP melalui penambahan H2O2 dapat meningkatkan pembentukan OHâ—,hal ini ditandai dengan kecilnya nilai Kla O3 pada variasi ozon/H2O21,795 g/L yaitu sebesar0,0023 dibandingkan variasi lainnya seperti ozon konvensional dan ozon/H2O21,197 g/L(0,0047 dan 0,0026). Proses dengan AOP (ozon/H2O21,795 g/L) menunjukkan hasil yang terbaik, kecilnya kelarutan ozon pada proses AOP mengindikasikan banyaknya ozon yang terdekomposisi menjadi OHâ—dan proses didominasi oleh reaksi tidak langsung melalui OHâ—.Kata kunci: Lindi, Kla O3 ,Ozon dan H2O2, OHâ—</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2015-10-05</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/734</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v3i2.%p</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 3, No 2 (2015); 53-62</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/734/936</dc:relation>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/3132</identifier>
				<datestamp>2021-03-02T16:19:08Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Tingkat Partisipasi Masyarakat dalam Pengelolaan Air Limbah Domestik di Kelurahan Cigadung</dc:title>
	<dc:creator>FAUZAN, SARA NISSA</dc:creator>
	<dc:creator>SOEMIRAT, JULI</dc:creator>
	<dc:creator>SURURI, M. RANGGA</dc:creator>
	<dc:subject xml:lang="id-ID"></dc:subject>
	<dc:description xml:lang="id-ID">AbstrakPartisipasi masyarakat dalam pengelolaan air limbah domestik diartikan sebagai kesadaran dan keterlibatan langsung masyarakat dalam mengelola air limbahsehinggamuncul rasa bertanggung jawab akan pentingnya mengelola limbah yang akan berpengaruh terhadap kesehatan masyarakat dan lingkungan sekitar. Tujuan penelitian ini adalah mengukur tingkat partisipasi masyarakat terhadap sistem pengelolaan air limbah domestik di Kelurahan Cigadung. Pengukuran tingkat partisipasi masyarakat menggunakan Konsep Arnstein(A Ladder Of Citizen Participation). Metode pengumpulan data dilakukan dengan wawancara. Teknikstratified dansistematis samplingdigunakanuntukmenentukanjumlahsampel. Hasil pengukuran menunjukkan tingkatpartisipasimasyarakattertinggiberadapada level manipulasiataurendahsebesar 90%. Disarankanadanyapendidikan formal dan informal, sertamemberikanpelayananpengelolaan air limbah yang terjangkau, handal, danbermanfaatuntukmeningkatkanpendapatanseperti biogas, komposting, dankolamstabilisasi.Â Kata kunci : Tingkat partisipasi, masyarakat, air limbah domestik</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2019-09-03</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/3132</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v6i2.%p</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 6, No 2 (2018)</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/3132/2002</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/6403</identifier>
				<datestamp>2022-11-28T21:19:48Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">ESTIMASI INHALATION EXPOSURE CONSENTRATION (IEC) PARTIKULAT TERESPIRASI DAN BLACK CARBON DI KAWASAN INDUSTRI DAERAH BANDUNG DAN CIMAHI</dc:title>
	<dc:creator>Fitria, Novi</dc:creator>
	<dc:creator>Jelsih, Marcelina</dc:creator>
	<dc:creator>Gunawan, Agie Adhitya</dc:creator>
	<dc:creator>Koesmawati, Tiny Agustini</dc:creator>
	<dc:subject xml:lang="id-ID">partikulat terespirasi, black carbon (BC), Inhalation Exposure Concentration (IEC)</dc:subject>
	<dc:description xml:lang="id-ID">Salah satu dampak dari aktivitas industri adalah pencemaran udara ambien akibat paparan partikulat terespirasi dan Black Carbon (BC) yang berdampak pada kesehatan pekerjanya. Penelitian ini dilakukan di Kawasan Industri Kota Bandung dan Cimahi di lima (5) lokasi titik sampling yaitu Cibeureum, Cimahi, Padalarang, Bandung Wetan dan Buahbatu. Tujuan dari penelitian ini adalah menganalisis kualitas udara di area tersebut berdasarkan indeks ISPU dan Inhalation Exposure Concentration (IEC) dari TSP, PM10, PM2.5 dan BC. IEC dihitung sebagai potensi paparan partikulat respirasi dan BC kepada pekerja melalui jalur inhalasi. Studi ini membuktikan bahwa di Kawasan Industri daerah Bandung dan Cimahi mengandung BC rentang 0,90-1,65 Âµg/m3. Sedangkan tingkat pencemaran udara untuk PM2.5 di kawasan industri, daerah Bandung Wetan berada dikategori â€œSedangâ€ dan daerah Buahbatu menunjukkan kategori â€œTidak Sehatâ€. Hasil perhitungan IEC diketahui bahwa bagi pekerja outdoor dan masyarakat di kawasan industri daerah Bandung dan Cimahi terpapar IEC TSP berkisar 10,29-36,99 Âµg/m3; IEC PM10 berkisar 6,65-34,69 Âµg/m3; IEC PM2,5 antara 2,24-19,83Âµg/m3 dan BC ada di rentang 0,20-0,36Âµg/m3. PM2.5 dan PM10 berkorelasi positif dengan TSP dengan nilai korelasiÂ  berturut-turut r= 0,999 dan r = 0,909.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID">Kepala Pusat Sains dan Teknologi Nuklir Terapan (PSTNT) bidang Sains dan Aplikasi Teknologi Nuklir, Badan Tenaga Nuklir Nasional</dc:contributor>
	<dc:date>2022-06-08</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/6403</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v10i2.145-154</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 10, No 2 (2022); 145-154</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/6403/2937</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/9849</identifier>
				<datestamp>2024-01-18T23:56:24Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">PENURUNAN KADAR BOD, COD DAN TURBIDITY LIMBAH CAIR INDUSTRI BATIK MELALUI METODE KOMBINASI PRETREATMENT FILTRASI ADSORPSI DAN ELEKTROKOAGULASI</dc:title>
	<dc:creator>Febrianto, Muhammad Akbar</dc:creator>
	<dc:creator>Sujiwa, Akbar</dc:creator>
	<dc:creator>Shofwan, Moch</dc:creator>
	<dc:creator>Majid, Dian</dc:creator>
	<dc:subject xml:lang="id-ID">Limbah cair industri batik; Pretreatment Adsorpsi; Elektrokoagulasi.</dc:subject>
	<dc:description xml:lang="id-ID">AbstrakLimbah cair industri batik pada Industri Batik X di Kampung Batik Jetis, Jln P. Diponegoro, Lemah Putro, Kec. Sidoarjo, Kabupaten Sidoarjo, mengandung zat pencemar seperti BOD dan COD. Sebagai solusi, metode kombinasi Pretreatment Adsorpsi dan Elektrokoagulasi diajukan sebagai alternatif. Penelitian ini bertujuan untuk mengevaluasi efektivitas metode kombinasi tersebut. Untuk proses Pretreatment Adsorpsi, digunakan reaktor model kontinu, sementara Elektrokoagulasi diterapkan dengan sistem batch. Penelitian dilakukan dengan variasi tegangan: 5; 7,5; 10; dan 12,5 V. Hasilnya, metode kombinasi ini berhasil menurunkan kadar BOD, COD, dan Turbiditas pada limbah cair industri batik. Efisiensi terbaik diperoleh pada tegangan 12,5 Volt untuk BOD dengan konsentrasi akhir mencapai 200,5 mg/L (efisiensi 85,19%) dan Turbiditas akhir mencapai 1,25 NTU (efisiensi 99,92%). Sedangkan untuk COD, penurunan optimal tercapai pada tegangan 10 V dengan COD akhir sebesar 445,5 mg/L (efisiensi 87,15%).Â Kata kunci: Limbah cair industri batik, Pretreatment Adsorpsi, Elektrokoagulasi.AbstractThe wastewater from the batik industry at Industri Batik X in Kampung Batik Jetis, Jln P. Diponegoro, Lemah Putro, Kec. Sidoarjo, Kabupaten Sidoarjo, contains pollutants such as BOD and COD. As a solution, a combination of Pretreatment Adsorption and Electrocoagulation methods is proposed as an alternative. This research aims to evaluate the effectiveness of this combined method. For the Pretreatment Adsorption process, a continuous model reactor was used, while Electrocoagulation was applied with a batch system. The study was conducted with variations in voltage: 5 Volts, 7.5 Volts, 10 Volts, and 12.5 Volts. The results show that this combined method successfully reduced the levels of BOD, COD, and Turbidity in the wastewater from the batik industry. The best efficiency was achieved at 12.5 Volts for BOD, with a final concentration of 200.5 mg/L (85.19% efficiency), and a Turbidity of 1.25 NTU (99.92% efficiency). Meanwhile, for COD, the optimal reduction was reached at 10 Volts, resulting in a final COD concentration of 445.5 mg/L (87.15% efficiency).Keywords: Batik industrial liquid waste, Adsorption Pretreatment, Electrocoagulation.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2024-01-18</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/9849</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v11i3.258-269</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 11, No 3 (2023); 258-269</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/9849/3547</dc:relation>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/downloadSuppFile/9849/819</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/13717</identifier>
				<datestamp>2026-02-22T05:51:02Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">KAJIAN EFISIENSI IPAL PABRIK KELAPA SAWIT BERDASARKAN PARAMETER FISIKOKIMIA AIR</dc:title>
	<dc:creator>Astuty, Eka Puji</dc:creator>
	<dc:creator>Anshari, Gusti Zakaria</dc:creator>
	<dc:creator>Akbar, Aji Ali</dc:creator>
	<dc:subject xml:lang="id-ID">Efisiensi; IPAL; kelapa sawit; Limbah cair</dc:subject>
	<dc:description xml:lang="id-ID">Pabrik kelapa sawit menghasilkan limbah cair yang berpotensi mencemari lingkungan apabila tidak dikelola dengan baik. Instalasi Pengolahan Air Limbah (IPAL) pada PT. X di Kecamatan Sintang, Kabupaten Sintang, Provinsi Kalimantan Barat dirancang untuk menurunkan kadar pencemar utama, seperti Chemical Oxygen Demand (COD), Biological Oxygen Demand (BOD), Total Suspended Solids (TSS), pH, minyak dan lemak, serta nitrogen total. Penelitian ini bertujuan untuk mengevaluasi tingkat efisiensi pengolahan limbah cair pada unit IPAL, khususnya kolam anaerobik dan aerobik dengan menganalisis penurunan parameter COD, BOD, TSS, pH, minyak dan lemak, serta nitrogen total. Metode yang digunakan adalah analisis deskriptif kuantitatif berdasarkan hasil uji laboratorium terhadap sampel yang diambil dari kedua kolam tersebut. Hasil penelitian menunjukkan bahwa sistem IPAL mampu menurunkan COD sebesar 90,11%, minyak dan lemak sebesar 88,89%, BOD sebesar 86,59%, dan TSS sebesar 76,53%, yang dikategorikan sebagai sangat efisien hingga efisien. Namun, pengolahan terhadap parameter nitrogen total belum menunjukkan hasil yang optimal, dengan tidak efisiensi atau kurang &lt;20%. Ketidakefektifan ini disebabkan oleh faktor teknis, seperti rusaknya sebagian aerator dan pendangkalan kolam akibat akumulasi lumpur, yang berdampak pada waktu tinggal limbah yang tidak mencukupi. Oleh karena itu, perbaikan sistem aerasi dan pemeliharaan kolam secara berkala diperlukan guna meningkatkan efektivitas pengolahan secara menyeluruh.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID">Magister Ilmu Lingkungan Pascasarjana Universitas Tanjungpura Pontianak</dc:contributor>
	<dc:date>2025-10-28</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/13717</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v13i1.49-60</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 13, No 1 (2025); 49-60</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/13717/4104</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/1207</identifier>
				<datestamp>2022-07-21T15:37:19Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Pembuatan Rencana Perbaikan untuk Menangani Defisit Air di PDAM Kota Denpasar dengan Menggunakan Rencana Pengamanan Air Minum (RPAM)-Operator</dc:title>
	<dc:creator>Fajrin, Aditya</dc:creator>
	<dc:creator>S.Dj, Rachmawati</dc:creator>
	<dc:creator>Taroepratjeka, Dyah Asri Handayani</dc:creator>
	<dc:subject xml:lang="id-ID"></dc:subject>
	<dc:description xml:lang="id-ID">ABSTRAKTarget RPJMNadalah 100% akses air bersih pada tahun 2019. Akan tetapi, cakupan pelayanan PDAM Kota Denpasar pada akhir tahun 2014 baru sebesar 45,80%. PDAM Kota Denpasar mengalami kesulitan dalam pengembangan cakupan pelayanan karena adanya defisit air sebesar 391,54 L/det. Sehingga diperlukan penanganan defisit air untuk mendukung tercapainya target RPJMN. RPAM-Operator merupakan cara paling efektif untuk memastikan secara konsisten keamanan air minum melalui pendekatan analisa dan manajemen resiko.Untuk itu tujuan penyusunan jurnal ini adalah menyusun rencana perbaikan untuk menangani defisit air menggunakan RPAM-Operator. Pendekatan analisa dan manajemen resiko pada RPAM-Operator melalui proses identifikasi, penilaian, dan memprioritiskan berbagai resiko. Dari hasil penyusunan didapati PDAM Kota Denpasar memiliki 22 kejadian bahaya yang dapat menyebabkan defisit air,secara umumakibat pengaruh musim, aktifitas di hulu sungai, suplai listrik PLN dan kebocoran pipa distribusi.Untuk menangani kejadian bahaya tersebut diperlukan 38 tindakan pengendalian yang terdiri dari koordinasi, memasang unit baru, memperbaiki kerusakan dan melakukan pembersihan unit SPAM, dan membuat database. Setelah itu, dilakukan proses penilaian dan prioritas agar tindakan pengendalian tersusun menjadi rencana perbaikan.Hasil akhir didapatkan,sebanyak 24tindakan pengendalian dilaksanakan dalam jangka pendek (&lt;5 tahun), jangka menengah (5-10 tahun) sebanyak 9 tindakan pengendalian dan jangka panjang (&gt;10Â  tahun) sebanyak 5 tindakan pengendalian.Kata Kunci: RPAM-Operator, PDAM, SPAM</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2017-04-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/1207</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v5i1.%p</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 5, No 1 (2017)</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/1207/1412</dc:relation>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/4136</identifier>
				<datestamp>2022-03-06T18:22:34Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Evaluasi dan Optimalisasi Instalasi Pengolahan Lindi di TPK Sarimukti</dc:title>
	<dc:creator>Safria, Putri</dc:creator>
	<dc:creator>Perdana, Arief</dc:creator>
	<dc:subject xml:lang="id-ID">Lindi; IPL; Evaluasi; Optimalisasi</dc:subject>
	<dc:description xml:lang="id-ID">AbstrakInstalasi Pengolahan Lindi TPK Sarimutki terdiri dari Kolam Stabilisasi - Bak Pengumpul - Kolam Anaerobic Buffle Reactor (ABR) - Kolam Aerobik, Kolam Sedimentasi dan Land Treatment. Skema bangunan pengolah tersebut belum menunjukkan hasil yang optimal, dilihat dari kualitas lindi dan kuantitas yang sangat fluktuatif. Penelitian dilakukan dengan cara mengevaluasi kondisi eksisting kemudian membandingkan dengan peraturan dan standar baku mutu yang ada. Hasil evaluasi menunjukkan seluruh unit pengolahan memiliki permasalahannya masing-masing baik dari segi kualitas maupun kuantitas sehingga mempengaruhi kinerja IPL secara keseluruhan, oleh karena itu IPL TPK Sarimukti perlu melakukan optimalisasi/redesain pada setiap unit pengolahannya. Rencana optimalisasi IPL TPK Sarimukti secara berurutan terdiri atas Kolam Stabilisasi â€“ Bak Kontrol 1 â€“ Reaktor AOP â€“ Bak Kontrol 2 â€“ Kolam ABR â€“ Kolam Aerobik 1 â€“ Kolam Aerobik 2 â€“ Kolam Sedimentasi â€“ Reaktor Filtrasi â€“ Bak Effluen â€“ Badan air yang berupa sungai.Kata kunci: Lindi, IPL, Evaluasi, OptimalisasiAbstractThe Sarimutki Leachate Treatment Plant consists of a Stabilization Pond - Collecting Tub - Anaerobic Buffle Reactor (ABR) Pond - Aerobic Pond, Sedimentation Pond and Land Treatment. The processing building scheme has not shown optimal results, seen from the quality and quantity of leachate and which Â very fluktuatif. The research was conducted by evaluating the existing conditions and then comparing them with the existing regulations and quality standards. The results of the evaluation show that all processing units have their respective problems in terms of both quality and quantity which affect the overall performance of the IPL, therefore the IPL TPK Sarimukti needs to optimize / redesign each processing unit. The IPL optimization plan of the Sarimukti TPK sequentially consists of a stabilization pond - control basin 1 - AOP reactor - control basin 2 - ABR pool - Aerobic pool 1 - Aerobic pond 2 - Sedimentation pond - Filtration reactor - Effluent basin - Water bodies in the form of rivers.Keywords: Leachate, Lachate Treatmet Plant, Evaluation, Optimization</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID">UPTD Pengeloaan Sampah TPA/TPST Regional</dc:contributor>
	<dc:date>2021-06-04</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/4136</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v10i1.11-22</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 10, No 1 (2022); 11-22</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/4136/2566</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/8057</identifier>
				<datestamp>2024-02-15T00:11:44Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">SIMULATION OF PRESSURE REDUCING VALVE (PRV) INSTALLATION IN THE DISTRIBUTION NETWORK (CASE STUDY: NORTHERN REGION OF SUMBER IPA PALUKAHAN PDAM PADANG CITY)</dc:title>
	<dc:creator>Adetya, Ashifa</dc:creator>
	<dc:creator>Dewi, Nadia Tripermata</dc:creator>
	<dc:creator>Komala, Puti Sri</dc:creator>
	<dc:subject xml:lang="id-ID">EPANET, IPA Palukahan, Jaringan distribusi, Pressure Reducing Valve (PRV), Tekanan</dc:subject>
	<dc:description xml:lang="id-ID">ABSTRAKPenelitian ini bertujuan untuk mensimulasikan lokasi pemasangan Pressure Reducing Valve (PRV) yang tepatÂ  pada jaringan perpipaan di Wilayah utara Perumda Air Minum (PDAM) Kota Padang menggunakan satu sumber air. Simulasi hidrolis menggunakan aplikasi EPANET serta data sekunder dari PDAM Padang. Data yang dibutuhkan untuk simulasi terdiri dari data debit reservoir, pelanggan wilayah utara, serta perpipaan. Hasil simulai EPANET kemudian dibandingkan dengan hasil pengukuran lapangan. Terdapat perbedaan tekanan yang cukup signifikan antara simulasi EPANET dengan hasil pengukuran lapangan. Tingginya tekanan hasil simulasi, karena sumber air IPA Palukahan yang memiliki perbedaan elevasi yang besar dengan daerah pelayanan. Pemasangan Pressure Reducing Valve (PRV) merupakan pilihan untuk mengurangi tekanan pada jaringan pipa sampai batas tertentu. Dalam simulasi lokasi pemasangan PRV yang tepat di jaringan distribusi ditentukan agar tekanan di daerah pelayanan yang diperoleh memenuhi persyaratan. Rekomendasi penempatan PRV antara Node 119 dan Node 120 pada ketinggian 30 mdpl. PRV dapat menurunkan tekanan dari 1,9 atm â€“ 10,7 atm menjadi 1,2 atm â€“ 6,9 atm. Pemasangan PRV dapat menjadi langkah awal dalam persiapan pembentukan DMA (District metered Area) di wilayah utara kota Padang dalam rangka menurunkan tingkat kebocoran air.Kata kunci: EPANET, Instalasi Pengolahan Air (IPA) Palukahan, Jaringan distribusi, Pressure Reducing Valve (PRV), TekananABSTRACTThis study aims to simulate the exact location of the Pressure Reducing Valve (PRV) installation in the pipeline network in the northern area of the Municipal Water Supply Company (PDAM) of Padang City using one water source. The water source used is Palukahan Water Treatment Plant (WTP) which has a relatively high elevation to the service area. The hydraulic simulation used the EPANET and secondary data from PDAM Padang. The data needed for the simulation consists of reservoir discharge data, northern customers, and piping. The results of the EPANET simulations were then compared with the results of field measurements. There is a significant difference in pressure between the EPANET simulation and the field measurement results. The high pressure from the simulation results is due to the Palukahan WTP water source which has a large elevation difference from the service area. Installation of a Pressure Reducing Valve (PRV) is an option to reduce the pressure in the pipe network to a certain extent. In the simulation, the appropriate PRV installation location in the distribution network is determined so that the pressure in the service area obtained meets the requirements. Recommended PRV placement between Node 119 and Node 120 at an altitude of 30 meters above sea level. PRV can reduce pressure from 1.9 atm â€“ 10.7 atm to 1.2 atm â€“ 6.9 atm. Installing PRV can be the first step in preparing for the formation of a DMA in the northern area of Padang City in order to reduce the level of water leakage.Keywords: EPANET, Palukahan Water Treatment Plant (WTP), Distribution Network, Pressure Reducing Valve (PRV), Padang Water Utility (PDAM Padang), Pressure</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2023-10-31</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/8057</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v11i2.173-183</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 11, No 2 (2023); 173-183</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/8057/3439</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/12514</identifier>
				<datestamp>2025-07-02T08:03:41Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">ANALISIS SPASIO-TEMPORAL PENGARUH CURAH HUJAN TERHADAP POLUSI UDARA KARBON MONOKSIDA DI KOTA BANDUNG TAHUN 2023: PENDEKATAN BERBASIS DATA SATELIT</dc:title>
	<dc:creator>Ramadhan, Eka</dc:creator>
	<dc:creator>Hadi, Firman</dc:creator>
	<dc:creator>Yusuf, Muhammad Adnan</dc:creator>
	<dc:subject xml:lang="id-ID">curah hujan, karbonmonoksida, pengindraan jauh, polusi udara.</dc:subject>
	<dc:description xml:lang="id-ID">Karbon Monoksida (CO) termasuk ke dalam primary pollutants yang paling banyak menyebabkan masalah pencemaran udara sebesar 58%. Sumber utama CO adalah emisi kendaraan bermotor. Jumlah kendaraan bermotor di Kota Bandung hampir setara dengan jumlah penduduknya, yaitu mencapai 2,2 juta unit, sedangkan penduduknya berjumlah 2,4 juta jiwa. Selain itu, tahun 2023 menjadi periode dengan jumlah kejadian kebakaran terbanyak (352 kejadian). Oleh karena itu, analisis spasio-temporal polusi udara CO penting dilakukan untuk monitoring pencemaran udara. Tujuan penelitian ini adalah menganalisis distribusi spasial dan temporal konsentrasi CO serta pengaruh curah hujan terhadap konsentrasi CO di Kota Bandung tahun 2023 dengan menggunakan metode pengindraan jauh. Hasil penelitian menunjukkann akumulasi CO tertinggi dan terendah berada di Kecamatan Bandung Kidul dan Cidadap (880,88 µg/m³ dan 827,04 µg/m³). Selain itu, akumulasi CO tertinggi terjadi selama periode bulan kering (curah hujan &lt;100 mm). Analisis korelasi dan regresi menunjukkan pada periode bulan kering terdapat korelasi positif yang kuat (r=0,56) serta pengaruh curah hujan yang lebih besar   terhadap konsentrasi CO dibandingkan periode bulan lainnya. Temuan penelitian ini menunjukkan perlu dilakukan pemantauan kualitas udara di Kota Bandung pada bulan kering agar dapat menekan peningkatan karbon monoksida.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2025-02-04</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/12514</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v12i3.269-282</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 12, No 3 (2024); 269-282</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/12514/3855</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/3857</identifier>
				<datestamp>2022-11-14T05:46:10Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Analisis Biaya Pengangkutan Sampah Rumah Tangga Eksisting di Kota Cimahi</dc:title>
	<dc:creator>HERYENI, SITI S. ANGGUNISA</dc:creator>
	<dc:creator>PRATAMA, YULIANTI</dc:creator>
	<dc:creator>HALOMOAN, NICO</dc:creator>
	<dc:subject xml:lang="id-ID"></dc:subject>
	<dc:description xml:lang="id-ID">AbstrakBiaya rerata pengelolaan sampah di Kota Cimahi (2012-2016) mencapai Â±13 miliar rupiah dengan penerimaan rerata retribusi sampah hanya Â±1 miliar rupiah. Biaya pengelolaan sampah kota dipengaruhi oleh timbulan sampah, dimana sebesar 63% sampah kota berasal dari permukiman dengan penerimaan retribusi sampah (permukiman) rerata (2012-2016) hanya Â±784 juta rupiah. Retribusi sampah dipungut untuk membayar jasa pengangkutan sampah. Biaya pengangkutan di Kota Cimahi akan semakin meningkat dikarenakan mulai tahun 2021-2037 TPA Sarimukti akan ditutup dan dialihkan ke TPA Legok Nangka dengan jarak yang lebih jauh, sehingga pada penelitian ini dilakukan analisis biaya pengangkutan sampah rumah tangga eksisting di Kota Cimahi. Metode analisis data yang digunakan adalah deskriptif-kuantitatif. Analisis biaya pengangkutan dilakukan dengan membandingkan penerimaan retribusi sampah dengan biaya pengangkutan, serta dilakukan perbandingan dengan Kota Yogyakarta. Berdasarkan hasil analisis diperoleh bahwa kontribusi penerimaan retribusi sampah permukiman terhadap biaya pengangkutan hanya 19%, artinya kontribusi penerimaan retribusi sampah relatif kecil dan tidak dapat dijadikan sumber anggaran utama. Kata kunci: Biaya Pengangkutan Sampah, Retribusi Sampah Rumah Tangga, Kota CimahiAbstractThe average cost of solid waste management in Cimahi City (2012-2016) reaches Â± 13 billion rupiah with the average revenue of waste levies is only Â± 1 billion rupiah. The cost of municipal solid waste management is influenced by waste generation, which 63% of the waste comes from household with average waste collection (household) (2012-2016) is only Â± 784 million rupiah. Data analysis method used is descriptive-quantitative. Transportation cost analysis is done by comparing the acceptance of wastecollection with transportation cost, and comparing with Yogyakarta city. Based on the analysis result, it is found that the contribution of waste collection with transportation cost is only 19%, that means the contribution of waste retribution acceptance is relatively small and can not be used as the main budget source.Â Keywords: Cost of Transportating Waste, Domestic Waste Collection, Cimahi City </dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2020-03-03</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/3857</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v8i1.50-58</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 8, No 1 (2020); 48-56</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/3857/2290</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/7692</identifier>
				<datestamp>2023-10-31T20:13:48Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">ADSORPSI LOGAM BERAT KROM (Cr) DAN ZAT WARNA DENGAN ADSORBEN KULIT PISANG KEPOK DALAM AIR LIMBAH BATIK</dc:title>
	<dc:creator>Dini, Latansa</dc:creator>
	<dc:creator>Kusumadewi, Riana Ayu</dc:creator>
	<dc:creator>Hadisoebroto, Rositayanti</dc:creator>
	<dc:subject xml:lang="id-ID">Kulit Pisang Kepok, Logam Berat Cr, Zat Warna, Adsorpsi, Reaktor Berpengaduk</dc:subject>
	<dc:description xml:lang="id-ID">Air limbah dari industri batik pada umumnya dibuang langsung ke badan air tanpa diolah terlebih dahulu. Proses adsorpsi menggunakan adsorben kulit pisang kepok dapat menyisihkan bahan pencemar dalam air limbah batik. Tujuan dari penelitian ini adalah untuk mengetahui kinerja kulit pisang kepok sebagai adsorben dalam menyisihkan logam berat krom (Cr) dan zat warna dalam air limbah batik. Pembuatan adsorben kulit pisang kepok dilakukan dengan mengeringkan dan mengkarbonisasi menggunakan tanur hingga menjadi serbuk arang. Selanjutnya kulit pisang kepok diaktivasi dengan merendamnya selama 24 jam dalam larutan H2SO4 20%. Variasi kecepatan pengadukan sebesar 100 rpm dan 200 rpm dengan waktu kontak sebesar 15, 30, 60, 75, dan 90 menit. Konsentrasi awal logam berat Cr dalam air limbah batik sebesar 0,4173 mg/L. Efisiensi penyisihan logam berat Cr optimum sebesar 100% diperoleh pada kecepatan pengadukan 100 rpm dan waktu kontak 15 menit. Sementara efisiensi penyisihan zat warna optimum sebesar 42,98% diperoleh pada kecepatan pengadukan 200 rpm dan waktu kontak 90 menit. Isoterm adsorpsi pada penelitian ini mengikuti persamaan Isoterm Freundlich dengan nilai R2 sebesar 0,9999 dan kinetika adsorpsi mengikuti kinetika orde dua dengan R2 sebesar 0,9995.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2023-06-15</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/7692</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v11i1.37-48</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 11, No 1 (2023); 37-48</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/7692/3322</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/11367</identifier>
				<datestamp>2024-10-21T21:41:20Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">ANALISIS TINGKAT KEBISINGAN LINGKUNGAN AKIBAT REVITALISASI DI JEMBATAN JURUG SURAKARTA</dc:title>
	<dc:creator>Rachmawati, Siti</dc:creator>
	<dc:creator>Mahendra, Abel Surya</dc:creator>
	<dc:creator>Gestan, Distayana Alda</dc:creator>
	<dc:creator>Ramadhani, Glora</dc:creator>
	<dc:creator>Koesdaryanto, Nilam Sariramadhani</dc:creator>
	<dc:creator>Karina, Ressa</dc:creator>
	<dc:creator>Firmansyah, Fathoni</dc:creator>
	<dc:subject xml:lang="id-ID">Revitalisasi, Kebisingan, Kendaraan, Jalan Raya, Sound Level Meter</dc:subject>
	<dc:description xml:lang="id-ID">Kota Surakarta sebagai salah satu kota yang terus berkembang, menjadikan pemerintah setempat berupaya untuk memperbaiki infrastruktur dan memenuhi kebutuhan transportasi masyarakat. Revitalisasi Jembatan Jurug menjadi proyek cukup besar karena jembatan ini berperan sebagai jalur vital penghubung Solo-Karanganyar. Revitalisasi ialah suatu proses atau cara dan perbuatan untuk menghidupkan kembali suatu hal yang sebelumnya terberdaya. Proyek ini berdampak pada lingkungan sekitar akibat bertambahnya volume kendaraan yang menyebabkan gangguan kenyamanan dan kualitas hidup masyarakat di sekitar jembatan, yaitu kebisingan. Dampak kebisingan akan berpengaruh terhadap kesehatan masyarakat seperti gangguan pendengaran ataupun non pendengaran yang mana apabila kebisingan ini berlebih dapat menyebabkan gangguan tidur, stres, masalah pendengaran, dan mengganggu aktivitas sehari-hari. Tujuan dari adanya penelitian ini yaitu untuk mengetahui tingkat kebisingan di Kawasan Jembatan Jurug, mengetahui faktor penyebab kebisingan di kawasan Jembatan Jurug, serta mengetahui pengaruh kebisingan di Kawasan Jembatan Jurug terhadap kenyamanan masyarakat sekitar. Metode yang digunakan berupa riset kepustakaan dan riset lapangan yaitu dengan dilakukan penghitungan kebisingan menggunakan Sound Level Meter dan penghitungan jumlah kendaraan di dua hari dan waktu yang berbeda. Berdasarkan pengujian yang dilakukan, tingkat kebisingan di Jembatan Jurug telah melewati standar baku mutu dan didapati ketinggian pemetaan kebisingannya serta revitalisasi ini berakibat mengganggu kenyamanan masyarakat.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2024-10-22</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/11367</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v12i2.159-171</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 12, No 2 (2024); 159-171</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/11367/3734</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/1043</identifier>
				<datestamp>2023-03-01T06:27:07Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Studi Tingkat Partisipasi Pedagang dalam Pengelolaan Sampah Berbasis 3r di Pasar Induk Gedebage</dc:title>
	<dc:creator>NURFITRIANA, WISYE</dc:creator>
	<dc:creator>HARTATI, ETIH</dc:creator>
	<dc:creator>AINUN, SITI</dc:creator>
	<dc:subject xml:lang="id-ID"></dc:subject>
	<dc:description xml:lang="id-ID">ABSTRAKSalah satu sumber penyebab tingginya jumlah timbulan sampah di perkotaan adalah sampah yang berasal dari pasar. Pasar Induk Gedebage memiliki timbulan sampah sebesar 60.413,7 liter/hari atau 16.357,5 kg/hari. Komposisi sampah di pasar tersebut didominasi oleh sampah organik sebesar 55%, sebaiknya dapat dilakukan sistem pengelolaan sampah seperti pengomposan ataupun dengan alternatif lain. Sistem pengomposan tersebut tidak berjalan karena kurang adanya partisipasi. Sistem tersebut dapat berjalan optimal apabila adanya partisipasi dari para pedagang untuk melakukan pemilahan sampah mulai dari sumber, maka diperlukan identifikasi tingkat partisipasi pedagang. Pengukuran tingkat partisipasi pedagang tersebut menggunakan kuisioner. Sistem pengomposan tidak memiliki efisiensi dalam pengurangan timbulan sampah, efisiensi pengurangan sampah barang lapak sebesar 0,35%, dan SPA sebesar 68,1%. Metode kuisioner yang diolah menggunakan diagram kartesius tersebut bahwa pedagang sayur, buah, daging, beras, plastik dan kelontong memiliki tingkat keinginan tinggi dan pengetahuan rendah. Pedagang grosir memiliki tingkat keinginan rendah dan pengetahuan rendah, sedangkan pedagang kue memiliki keinginan tinggi dan pengetahuan tinggi.Kata Kunci : Sampah, Pengelolaan sampah berbasis 3R, Efisiensi, Tingkat partisipasi.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2016-09-08</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/1043</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v4i2.%p</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 4, No 2 (2016); 57-65</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/1043/1268</dc:relation>
</oai_dc:dc>
			</metadata>
		</record>
		<record>
			<header>
				<identifier>oai:ojs.ejurnal.itenas.ac.id:article/14503</identifier>
				<datestamp>2026-04-03T02:44:45Z</datestamp>
				<setSpec>lingkungan:ART</setSpec>
			</header>
			<metadata>
<oai_dc:dc
	xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/
	http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">KUALITAS AIR LIMBAH RSPI SULIANTI SAROSO</dc:title>
	<dc:creator>Tiardjiono, Mulya</dc:creator>
	<dc:creator>Nurlaela, Nurlaela</dc:creator>
	<dc:creator>Setyawati, Fajar Dwi</dc:creator>
	<dc:creator>Nurhenifah, Eka Erlis</dc:creator>
	<dc:creator>Anggraeni, Yeyen</dc:creator>
	<dc:creator>Wijiarti, Kunti</dc:creator>
	<dc:creator>Pratiwi, Tiara Zakiyah</dc:creator>
	<dc:creator>Rivaldiansyah, Rivaldiansyah</dc:creator>
	<dc:creator>Maemun, Siti</dc:creator>
	<dc:subject xml:lang="id-ID">air limbah; baku mutu; rumah sakit</dc:subject>
	<dc:description xml:lang="id-ID">Rumah sakit memiliki peran penting dalam merawat pasien sakit. Namun  rumah sakit juga mempunyai kewajiban untuk memelihara lingkungan sekitar dari pencemaran limbah yang dihasilkan.  Penelitian ini merupakan studi kuantitatif yang bersifat deskriptif, bertujuan untuk menganalisis kualitas air limbah di RSPI Sulianti Saroso berdasarkan parameter pH, BOD, COD, zat padat tersuspensi (TSS), minyak dan lemak, amoniak, total koliform, zat organik (KmNO4), serta senyawa akibat biru metilen (MBAS) dari tahun 2022 sampai dengan 2024. Pengambilan sampel dilakukan di outlet Instalasi Pengolahan Air Limbah (IPAL) rumah sakit, dengan analisis yang dilakukan oleh Laboratorium Kesehatan Lingkungan Jakarta dan PT Unilab Perdana. Parameter yang diuji meliputi pH, Biochemical Oxygen Demand (BOD), Chemical Oxygen Demand (COD), Total Suspended Solids (TSS), minyak dan lemak, amonia, total koliform, zat organik (KmNO4), dan senyawa aktif biru metilen (MBAS). Penelitian ini menggunakan data sekunder dari Instalasi K3 dan Kesling. Pengolahan data dilakukan secara deskriptif dengan microsoft excel, ditampilkan dalam bentuk tabular, teks, atau gambar dengan analisis rerata, deviasi baku, median, frekuensi, dan persentase. Hasil penelitian ini menunjukkan bahwa semua parameter yang diuji berada dalam batas baku mutu yang ditetapkan. Sehingga pengelolaan air limbah berlangsung sesuai prosedur dan hasilnya efektif. Namun, pemantauan terus-menerus dan optimalisasi sistem pengolahan direkomendasikan untuk menjaga kepatuhan dan meningkatkan kualitas air limbah lebih lanjut.</dc:description>
	<dc:publisher xml:lang="id-ID">Institut Teknologi Nasional, Bandung</dc:publisher>
	<dc:contributor xml:lang="id-ID"></dc:contributor>
	<dc:date>2026-03-05</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="id-ID"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/14503</dc:identifier>
	<dc:identifier>10.26760/rekalingkungan.v13i2.177-192</dc:identifier>
	<dc:source xml:lang="id-ID">Jurnal Reka Lingkungan; Vol 13, No 2 (2025); 177-192</dc:source>
	<dc:source>2722-6077</dc:source>
	<dc:source>2337-6228</dc:source>
	<dc:language>ind</dc:language>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/view/14503/4322</dc:relation>
	<dc:relation>https://ejurnal.itenas.ac.id/index.php/lingkungan/article/downloadSuppFile/14503/1404</dc:relation>
	<dc:rights xml:lang="id-ID">##submission.copyrightStatement##</dc:rights>
</oai_dc:dc>
			</metadata>
		</record>
		<resumptionToken expirationDate="2026-04-05T00:03:41Z"
			completeListSize="171"
			cursor="0">5ceb9ac999a80a5f0e3cfb7c8cf25007</resumptionToken>
	</ListRecords>
</OAI-PMH>
